- ページ 38
スイッチ HP surestore fc 2Gb entry switch 8BのPDF マニュアルをオンラインで閲覧またはダウンロードできます。HP surestore fc 2Gb entry switch 8B 50 ページ。 Fabric os procedures guide (version 3.0)
4
Displaying Error Logs and Status
Displaying the Temperature Status
To display the temperature status of a switch:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
tempShow
This command displays current temperature readings from each of the five temperature sensors
located on the main printed circuit board of the switch. The sensors are located, approximately,
one in each corner and one at the center of the PCB.
Running Diagnostic Tests on the Switch Hardware
There are several diagnostic tests you can run on a switch. These test are generally run during the
POST, each time a switch is booted up.
•
camtest
•
centralMemoryTest
•
cmemRetentionTest
•
cmiTest
•
crossPortTest
•
portLoopbackTest
•
sramRetentionTest
•
turboRamTest
•
statsTest
•
spinSilk
4-6
Fabric OS Procedures Guide