Overflow Bulkhead Fitting
Funnel
Drain Line Barb
Putting it all together - Overview
Once you've identified all of the components of your softener, you're ready to begin the
installation. First, you'll want to locate a good spot for your softener. All parts of your water
softener should be located in a protected, dry, level, non-freezing area. The water softener needs
to be located in very close proximity to your water main, and also needs to be located close to a
drain. Suitable drains include a floor drain, sump pit, washing-machine drain, or (where
regulations permit) an outside downspout or gutter drain. It's important that you identify and
follow any local plumbing codes for the installation of your softener.
The drain line can be routed down to the floor or overhead. Whichever method is used please
ensure that all turns are gradual to prevent kinking in the line. Be sure to secure the drain line in
place as the pressure of the draining softener will move an unsecured line.
The softener you have purchased requires power in order to operate the valve. Ideally, you
should position the water softener a few feet from a power outlet. aQuatell recommends that all
water purification equipment, including softeners, be plugged into a Ground Fault Circuit
Interrupter (GFCI) outlet.
Check that the resin tank is sitting flat in the black plastic boot on the bottom of the tank. If the
boot appears to be on an angle push down on the resin tank and rock the tank very slightly back
and forth to lower the resin tank fully into the boot.
Putting it all together - The Softening Tank
The softening tank houses the resin and is where the softening of your water occurs. The
softening tank is the cylindrical tank with a threaded opening at the top. Set the softening tank in
the desired location. Insert the riser tube into this tank so that the slotted basket is at the bottom
of the softening tank. At the open end of the riser tube cover the opening with a piece of tape.
Now place the funnel in the opening of the softening tank and add the resin: