- ページ 10

電源 Diamond Systems Jupiter-MM-5000のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Diamond Systems Jupiter-MM-5000 18 ページ。 Advanced technology 218w dc/dc power supply pc/104-plus module

4.8

Remote On/Off

The power supply can be switched on and off remotely in two ways; through a discrete logic input or through a
programmable serial command.
For the discrete logic input, a 2-pin connector is used to provide an on/off control and ground. Driving the on/off
control to a logic 0, or shorting it to the power supply common, will shut off all supply outputs (except the auxiliary
+5V for the microcontroller and power controller circuit). The control input has a pull-up resistor to drive it to a
default on state. The remote on/off circuit is always operational when appropriate power is supplied through either
the main input or the backup / battery input connections.
Usage of the programmable serial command remote on/off can be found in the Janus-MM-5000 Software Users
Manual.
4.9

Advanced System Controller

The intelligent Jupiter-5000 models include a system controller that offers advanced configuration, control, and
monitoring features. The system controller is accessed via a USB port and is accompanied by benchtop
configuration software as well as an application library for in-application real-time control.
Individual supply on/off control for +12V, +5V, and +3.3V outputs
Individual supply output voltage / current monitoring
Output voltage sequencing and slew rate control
Output voltage adjustment
Input voltage monitoring
Fault handling based on programmable limits with interrupt notification, including supply shutdown in case of
overload or other programmed conditions
Hiccup mode for auto-restart when fault conditions are removed
Min / max voltage and temperature logging
Secondary input cutover voltage selection
Information on using the advanced systems controller can be found in the Janus-MM-5000 Software Users Manual.
JMM-5000 User Manual Rev B.01
www.diamondsystems.com