- ページ 32
プロジェクター Panasonic PT-LB10U - Mobile Projector XGA 2000 LumensのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Panasonic PT-LB10U - Mobile Projector XGA 2000 Lumens 33 ページ。 Micro portable xga lcd projector
Panasonic PT-LB10U - Mobile Projector XGA 2000 Lumens にも: パンフレット&スペック (4 ページ)
Using the SERIAL connector
The serial connector which is on the connector panel of the projector
conforms to the RS-232C interface specification, so that the projector can be
controlled by a personal computer which is connected to this connector.
Connection
Computer
SERIAL(female)
DIN 8-pin (male)
Serial adapter
(ET-ADSER : sold
separately)
You must use only RS-232C Serial
Interface Cable with ferrite core,
type ET-ADSER.
Pin assignments and signal
names
1
2
3
5
6
8
DIN 8-pin
Appearance
Pin
Signal
Contents
No.
name
%
RXD Received data
&
GND Earth
'
TXD Transmitted data
#
$
Connected internally
(
)
NC
*
NC
62-E
NGLISH
Communications settings
Signal level
RS-232C
Sync. method
Asynchronous
Baud rate
9 600 bps
Parity
None
Character length 8 bits
Stop bit
1 bit
X parameter
None
S parameter
None
Basic format
The data sent from the computer to
the projector is transmitted in the
format shown below.
STX Command : Parameter ETX
Start byte
1 byte
End byte
(02h)
(03h)
3 bytes
1 byte-5 bytes
NOTE:
B The projector can not receive
the command for 10 seconds
after the lamp is switched on.
Wait 10 seconds before sending
the command.
B If sending multiple commands,
check that a response has been
received from the projector for
one command before sending
the next command.
B When a command which does
not require parameters is sent,
the colon (:) is not required.
B If an incorrect command is sent
from the personal computer, the
"ER401" command will be sent
from the projector to the
personal computer.
Control commands
The commands which the personal computer can use to control the projector
are shown in the following table.
Control
Command
Contents
In standby mode, all commands other than
the PON command are ignored.
PON
Power ON
B The PON command is ignored during
lamp ON control.
B If a PON command is received while the
cooling fan is operating after the lamp
has switched off, the lamp is not turned
POF
Power OFF
back on again straight away, in order to
protect the lamp.
Parameter
AVL
Volume
000-063 (Adjustment value 0-63)
Parameter
Input signal
VID=VIDEO
IIS
selection
RG1=RGB (YP
NWP=NETWORK (PT-LB10NTU only)
Callback
0 = Standby
Lamp ON
Q$S
1 = Lamp ON control active
condition query
2 = Lamp ON
3 = Lamp OFF control active
Cable specifications
(When connected to a personal computer)
At the projector
1
2
3
4
5
6
7
8
Remarks
SVD=S-VIDEO
P
)
B
R
At the computer
(DTE specifications)
7
8
3
5
2
6
1
4
9
E
-63
NGLISH