- ページ 11
スイッチ 3Com 3C16460のPDF データシートをオンラインで閲覧またはダウンロードできます。3Com 3C16460 12 ページ。 Superstack ii baseline hubs and switches
3Com 3C16460 にも: ユーザーマニュアル (9 ページ)
Specifications
SuperStack II Baseline Hubs and Switches
SuperStack II
Baseline Hubs
3C16440 (12 port)
3C16441 (24 port)
Functional: ISO 8802/3;
IEEE 802.3 (Ethernet)
Media Interfaces: 12/24
shielded RJ-45 TP; ARPS
connector (60 W Type 1);
Transceiver Interface Module
slot
Indicators per unit: Power;
Network Traffic; Collisions
Indicators per port: Link Status;
Partition
MAC Addresses: N/A
Safety: IEC 950; UL 1950;
CSA 22.2 No. 950; EN 60950
Electromagnetic: EN 55022
Class B* and Class A;FCC Part 15
Subpart B Class A; ICES-003
Class A; VCCI Class B* and
Class A; AS/NZS 3548 Class B*
and Class A; EN 50082-1
Environmental
EN 60068 (IEC 68)
Operating temperature: 0° to
50°C (32° to 122°F)
Operating Humidity: 10% to
95% (noncondensing)
Storage temperature: -10° to
+70°C (14° to 158°F)
Storage Humidity: 10% to 95%
(noncondensing)
Physical
Width: 440 mm (17.3 in)
Height: 44 mm (1.7 in), or 1U
Depth: 224 mm (8.8 in)
Weight: 2.04 kg (4.5 lb)
Electrical
Fuse Protection: 2 A
Power Inlet: IEC 320
Input Voltage Range: 100-240 V;
50-60 Hz
Power Consumption (Maximum):
12-port, 34 W; 24-port, 44 W
SuperStack II ARPS Connection:
60 W Type 1
Heat Dissipation (Maximum)
12 port: 116 BTU/hr
24 port: 150 BTU/hr
*Requires the use of Category 5 screened cables to comply with the requirements of this standard.
SuperStack II Baseline Dual
Speed Hubs
3C16592A (12 port)
3C16593A (24 port)
Functional: ISO 8802/3;
IEEE 802.3 (Ethernet);
IEEE 802.3u (Fast Ethernet)
Media Interfaces: 12/24
shielded RJ-45 TP; ARPS
connector (60 W Type 1)
Indicators per unit: Power;
Network Traffic (per segment);
Collisions (per segment)
Indicators per port: Link Status;
Partition
MAC Addresses: 4,000
Safety: IEC 950; UL 1950;
CSA 22.2 No. 950; EN 60950
Electromagnetic: EN 55022
Class B* and Class A; FCC Part
15 Subpart B Class A; ICES-003
Class A; VCCI Class B* and
Class A; AS/NZS 3548 Class B*
and Class A; EN 50082-1
Environmental
EN 60068 (IEC 68)
Operating temperature: 0° to
50°C (32° to 122°F)
Operating Humidity: 10% to
95% (noncondensing)
Storage temperature: -10° to
+70°C (14° to 158°F)
Storage Humidity: 10% to 95%
(noncondensing)
Physical
Width: 440 mm (17.3 in)
Height: 44 mm (1.7 in), or 1U
Depth: 173 mm (6.8 in)
Weight: 12 port: 2.1 kg (4.7 lb)
24 port: 2.3 kg (5 lb)
Electrical
Fuse Protection: 5 A
Power Inlet: IEC 320
Input Voltage Range:
100-120 V/200-240 V; 50-60 Hz
Power Consumption (Maximum):
12-port, 84 W; 24-port: 130 W
SuperStack II ARPS Connection:
60 W Type 1
Heat Dissipation (Maximum)
12 port: 86 BTU/hr
24 port: 142 BTU/hr
SuperStack II
Baseline Switches
3C16460 (12 port, 10 Mbps
switched ports plus 2 x 10/100
Mbps auto-sensing ports)
3C16462 (24 port, 10 Mbps
switched ports plus 2 x 10/100
Mbps auto-sensing ports)
Functional: ISO 8802/3;
IEEE 802.3 (Ethernet);
IEEE 802.3u (Fast Ethernet)
Media Interfaces: 14 shielded
RJ-45 TP; ARPS connector (60 W
Type 1)
Indicators per unit: Power
Indicators per port: Network
Traffic; Link Status; Speed
(10/100 Mbps ports); Full
Duplex (10/100 Mbps ports)
MAC Addresses: 12 port: 750;
24 port: 2,000
Safety: IEC 950; UL 1950;
CSA 22.2 No. 950; EN 60950
Electromagnetic: EN 55022
Class B*; FCC Part 15 Subpart B
Class A*; ICES-003 Class A*;
VCCI Class B*; AS/NZS 3548
Class B*; EN 50082-1
Environmental
EN 60068 (IEC 68)
Operating temperature: 0° to
50°C (32° to 122°F)
Operating Humidity: 10% to
95% (noncondensing)
Storage temperature: -10° to
+70°C (14° to 158°F)
Storage Humidity: 10% to 95%
(noncondensing)
Physical
Width: 440 mm (17.3 in)
Height: 44 mm (1.7 in), or 1U
Depth: 173 mm (6.8 in)
Weight: 2.04 kg (4.5 lb)
Electrical
Fuse Protection: 2 A
Power Inlet: IEC 320
Input Voltage Range: 100-240 V;
50-60 Hz
Power Consumption (Maximum):
48 W
SuperStack II ARPS Connection:
60 W Type 1
Heat Dissipation (Maximum)
12 port: 164 BTU/hr
24 port: 72 BTU/hr
SuperStack II
Baseline 10/100 Switches
3C16464A (12 port)
3C16465A (24 port)
Functional: ISO 8802/3;
IEEE 802.3 (Ethernet);
IEEE 802.3u (Fast Ethernet);
IEEE 802.3x (Flow Control)
Media Interfaces: 12/24
shielded RJ-45 TP; ARPS
connector (Type 2)
Indicators per unit: Power
Indicators per port: Network
Traffic; Link Status; Speed
(10/100 Mbps ports); Full
Duplex (10/100 Mbps ports)
MAC Addresses: 4,000
Safety: IEC 950; UL 1950;
CSA 22.2 No. 950; EN 60950
Electromagnetic: EN 55022
Class B* and Class A; FCC Part
15 Subpart B Class A; ICES-003
Class A; VCCI Class B* and
Class A; AS/NZS 3548 Class B*
and Class A; EN 50082-1
Environmental
EN 60068 (IEC 68)
Operating temperature: 0° to
50°C (32° to 122°F)
Operating Humidity: 10% to
95% (noncondensing)
Storage temperature: -10° to
+70°C (14° to 158°F)
Storage Humidity: 10% to 95%
(noncondensing)
Physical
Width: 440 mm (17.3 in)
Height: 44 mm (1.7 in), or 1U
Depth: 235 mm (9.3 in)
Weight: 2.6 kg (5.8 lb)
Electrical
Fuse Protection: 1 A
Power Inlet: IEC 320
Input Voltage Range: 100-240 V;
50-60 Hz
Power Consumption (Maximum):
200 W
SuperStack II ARPS Connection:
Type 2
Heat Dissipation (Maximum)
12 port: 165 BTU/hr
24 port: 300 BTU/hr
11