無線アクセスポイント Alpha IP FAL 41011-10のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Alpha IP FAL 41011-10 17 ページ。

Parameters
Time interval for pump
protection function
(only
available
for
Ch01)
Cooling in cooling
mode
Heating in heating
mode
Room with/without
external heat source
Selection of heating
system

9 Displays

9.1

LED System key

Display
Short flashing, orange
1 long lighting, green
1 long lighting, red
Short flashing, orange
(once every 10 seconds)
1 long lighting, red
6x long flashing, red
1 lighting in orange and
1 lighting in green
9.2

LED Heating zones

Display
Slow flashing
Double short flashing
Index
Value
P051
225
226
...
238 (default)
...
251
252
P052
0
1 (default)
P053
0
1 (default)
P054
0 (default)
1
2
P055
0 (default)
1
2
3
4
Meaning
Radio transmission/trans-
mission
attempt/data
transmission
Process confirmed
Process failed
Teach-in mode active
Process failed or duty cy-
cle limit reached
Device defective
Test indication
Meaning
Emergency operation ac-
tive
Bad radio connection to
wall thermostat
Meaning
1 day
2 days
...
14 days
...
27 days
28 days
inactive
active
inactive
active
without
with fireplace
with towel rail heating
Floor heating, standard
Floor heating, low energy
Radiator
Convector, passive
Convector, active
Solution
Wait until the transmission has ended.
You can continue your operations.
Retry.
Enter the last four digits of the serial number of the
device for confirmation.
Retry.
Observe the information in your app or contact your spe-
cialist dealer.
You can proceed after the test indication has gone out.
Solution
Change the batteries of the wall thermostat, perform a
radio test, reposition the wall thermostat if necessary, re-
place a defective wall thermostat.
Change the position of the wall thermostat or use a re-
peater.
Displays