- ページ 6
防犯カメラ Epcom EYH003FAPのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Epcom EYH003FAP 8 ページ。 Hidden ccd camera
Options
1.LED Selector:
(3PINS: Top, Center, Bottom)
2.Sensitivity Adjustment:
High
"VR1"
3.Dwell Time Adjustment:
Min.
"VR2"
Adjustable from 2 to 40 sec.
4.Alarm control, Light
control or Recording
control
(N.O or N.C)
(3PINS: Top, Center, Bottom)
5.Pulse Control:
Once or twice
1
2
J2
4PINS: 2PAIRS w/jumper connector
6.Output Terminals:
-
N.C. N.O.
JP2
24 Hour/Anti-Tamper
7.Power: 12V DC
Standby Current: 3mA,
Working Current: 28mA
A. Top + Center w/black cap: Upon Walk-testing: Light
blinking (Disadvantages: Easy to identify as a security
system.)
J1
B. Center + Low w/black cap: No light blinking while
detecting. (Advantages: less obvious)
A. To raise sensitivity: Turn clockwise to detect longer distance
and wider pattern.
Low
B. To lower sensitivity: Turn counter clockwise for detection in
narrow areas.
For closure period of N.C/N.O relay connected to an alarm
panel, light control or recording control of time lapse VCR, etc.
A. Max. time: Turn counter clockwise.
Max.
B. Min. time: Turn clockwise.
Top + Center pins of "J4" must be selected to adjust the time
setting.
A. Top + Center w/black cap: Operate with "VR2" to adjust
time. (To set the relay output of the Light control or
Recording control, the time is selected by individual
preference or application.
B. Center + Bottom w/black jumper: Relay output can be set for
J4
Security control panel for only 2 seconds.
Note: N.C./N.O. relay output current: 1A 125 VAC, 2A 30 VDC.
Position 1: Set to "ONCE" for instant reaction when PIR
Position 2: Set to "Twice" when PIR detects someone 2 times
N.C.: Normally Closed
+
A. For connection to: Security panel or Light control CCTV
...etc.
B. With anti-tamper function for 24 hours.
N.O.: Normally Open Contacts
※P.S.: Relay output current: 1A 125VAC, 2A 24VDC
Caution:
The PIR is triggered by body movement, excluding fixed
objects, however, do not place in direct sunlight or reflected
sunlight.
Description
detects someone: and either the "alarm or Security
control panel" or "Recording control" will be
triggered immediately.
within 15 seconds.
0.5A 230VAC, 2A 24VDC
5