- ページ 8
産業機器 EPE AMW-0.16のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。EPE AMW-0.16 8 ページ。 Diaphragm accumulator
Special Instructions
Certification
All hydraulic accumulators are pressure vessels and are
subject to the national regulations and directives, valid at
the place of installation.
Diaphragm accumulator type AMW are designed and
manufactured as per CE/PED in accordance with Directive
2014/68/EU.
As per the provisions of Directive 2014/68/EU all
accumulators with V ≤ 1 ltr and PS ≤ 1000 bar (PS = max.
working pressure in bar) are not allowed to be CE marked
[Article 4 Clause 3] .
Accumulators of capacity greater than 1 ltr are available
with CE marking. When specified every shipping batch is
provided with a conformity declaration and use and
maintenance instructions.
Safety
All pressure vessels must be protected by means of a
pressure relief valve in accordance with Directive
2014/68/EU. Safety Blocks type-B are used for this
purpose.
The most important elements of the safety-related
equipment are the pressure measuring device (pressure
gauge), device for the preventing excess pressure (safety
valves), non-return valves and shut-off valves and devices
for de-pressurising (bleed valves). These functions can be
performed with individual components or integrated in the
form of a safety block type-B.
Special Instructions
It is strictly forbidden to:
- weld or solder or carry out any mechanical operations on
the accumulator.
- engrave or permanently stamp the surfaces of the
accumulator shell and / or carry out other operations that
could affect or change the mechanical properties of the
accumulator
- use the accumulator as a structural element: it should not
be subjected to stresses or loads.
- change the data of the nameplate and / or accumulator
without the permission of the manufacturer.
- use a different fluid than those designed for .
Installation
Before installation, you must perform a visual check to
verify that the accumulator has not suffered any damage
during shipping / handling. Verify that the requested type
matches with what stamped on the nameplate.
EPE Process Filters & Accumulators Pvt. Ltd., Techni Towers, C-54/A, APIE, Balanagar, Hyderabad - 500 037, Telangana, INDIA
Ph : +91 40 23778803 | Fax : +91 40 23871447 | [email protected] | www.epe-india.com
We recommend using the accumulator with a suitable
safety valve or a security safety block type B. This device
provides user and equipment protection against possible
damage caused by pressure surges, and also makes the
maintenance of the accumulator easier, so facilitating the
interception and the discharge.
Provide for a clearance of 200 mm above the gas pre-
charge valve to allow access to and control of the pre-
charge equipment.
These accumulators may be installed in any position from
horizontal to vertical (preferably with the pre-charge
valve at the top), and the identification details must be
visible.
Proceed to the assembly so that no abnormal force
affects the pipes connected directly or indirectly to the
accumulator, so we recommend the use of supporting
components and also fastening to avoid the transmission
of vibrations.
Make sure the fluid is compatible with the elastomer of
the diaphragm.
Check that the max. allowed accumulator pressure is
equal to or greater than that of the hydraulic circuit and
that the temperature during operation is maintained
within the range expected.
Make sure the fluid does not contain contaminants
and/or abrasive.
Disposal
Before the accumulator is sent for disposal or recycling, it
should always be discharged completely of the pre-
charge pressure and the gas valve unscrewed. Pre-
loading and checking kits are suited for this task.
For permanently sealed design Accumulators (Version-P)
the diaphragm is preferably damaged on a test rig or the
accumulator is carefully drilled (Ø ≥ 6 mm) on the gas
chamber using a suitable clamp . As the gas flowing out
can draw metal splinters or particles with it, safety
glasses must be worn.
Environmental Protection
Careless disposal of the accumulator and the residual
fluid contained therein can cause environmental
pollution.
Dispose the Accumulator in accordance with provisions
applicable in the country of use.
Fluid residues are to be disposed according to the
respective safety data sheets valid for the specific
hydraulic fluids.
8