III/1 Adjustment -
Display
© DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 Neusäß • Germany
Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 20200703
III. Adjustment / Programming
Upon delivery the parameters „P-8" (position „crawling speed") and
„P-7" (Position „OPEN) are adjusted to „000". If a door drive with
integrated position control system is connected, the control system auto-
matically switches to an adjustment mode. This permits to move the
door with the push buttons OPEN and CLOSE to the required positions
and thus adjust them precisely.
The control system automatically chooses for this operation the deadman
operation. All opening movements are done in the crawling speed,
without any restriction as to the opening distance. As soon as the para-
meters for the change of the speed to the „Crawling Speed OPEN" (P-8)
and the position „Door OPEN" (P-7) have been entered, this adjustment
mode is switched off and the control system changes to the adjusted
operation type (deadman or impulse; adjustment with Dip-Switch 1, see
page 05.023.17).
The control system has some parameters preadjusted ex works that can
be adjusted on site with the membrane keys on the lid of the casing.
If you press the central key (Enter) the display shows „P-X", X being either
a number from 1 to 9 or one of the letters A, b, C or d. This displays
the parameter that presently can be adjusted.
IMPORTANT: The parameters are combined in 2 groups: the
parameters „P-1" to „P-5" as well as „P-C" to„P-d" are accessible
without restriction. The parameters „P-6" to „P-b" only can be adjusted
by persons instructed in the use of the control system. In order to get to
these parameters, you have to press the arrows
time when the parameter „P-0" is displayed.
If none of the arrow-keys is pressed for more than 6 seconds, the display
automatically returns to the parameter „P-0". This prevents unauthorized
persons from modifying any adjusted values.
Technical Manual E8
Change from one parameter to the next
+ ENTER
Reduce the values of the parameters
Increase the values of the parameters
and
at the same
Page 05.023.09