- ページ 2

ソーラーパネル Epever LORA 433A/470AのPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Epever LORA 433A/470A 2 ページ。 Solar wireless collector

HUIZHOU EPEVER TECHNOLOGY CO., LTD
Step3 Connect antenna
The antenna connector of the EPEVER LORA adopts a 4G glue stick
antenna, which varies with the working frequency. An external antenna
complied with the working frequency is irreplaceable; other mismatched
antennas will affect product performance and damage the product severely.
Working
Frequency
LORA
Include
433/470MHZ
Include
LORA
868/915MHZ
Optional
Caution: As a wireless terminal, keep the antenna away from the human body as
far as possible during the operation process.
5. Configure EPEVER LORA (Optional)
In the "one to more" connection diagram, one LORA needs to be set as the
master mode, and the remaining devices are in slave mode. The frequency
and channel of the slave devices must be consistent with the master device.
Note: The master-slave mode of the EPEVER LORA has been configured at the
factory. Users can quickly distinguish the master and slave devices according to
the master-slave device number provided in the configuration table (shipped with
the EPEVER LORA). This chapter generally does not need to be performed.
Suppose the user needs to change the parameters of the master device and slave
devices. In that case, you can configure them according to the following process.
Configuring process:
Step1: First, transform the communication port of the EPEVER LORA into
the USB port by LLT M12-4 cable, USB adapter, and then connect the USB
port to the PC.
Note: The LLT M12-4 cable and USB adapter are optional accessories. Please
contact the sales in advance for customizing.
Step2: Click to open the EPEVER LORA tools in the PC and connect
EPEVER LORA successfully.
Step3: Click the "Read" button to display the EPEVER LORA's parameters.
Note: The EPEVER LORA tool is a special configuration tool, which is convenient
to configure the parameters of terminals. Customers can apply for it from our
business or technical personnel after purchasing our products.
Step4: Click the "mode" drop-down box and select the "master" to set the
current EPEVER LORA to the master mode (the factory default mode).
Applicable Antenna
3
TEL: +86-10-82894896/82894112/+86-752-3889706
Step5: Click the "mode" drop-down box and select the "slave" to set other
LORAs to the slave mode (
must be consistent with the master device
Step6: Finish the master-slave mode setting.
6. Applications
In the "one to more" connection diagram, one EPEVER concentrator
matched with several LORAs can connect the solar controller flexibly. The
user can remotely control the devices through the cloud platform and monitor
the real-time status.
Login into the cloud platform (https://iot.epsolarpv.com), remotely monitor the
real-time condition, or set the parameters.
Note: For new accounts, devices need to be manually added in the EPEVER cloud
before monitoring.
7. Specifications
Item
Working Frequency
Communication channel
Antenna connector
Communication Distance
Power
Average power consumption
Data transformer protocol
Environment temperature
Guarantee period
8. Dimension
Any changes without prior notice! Version number: 3.0
Website: www.epever.com
Note: The frequency and channel of the slave device
).
Specifications
433 MHz/470 MHz /868 MHz /915 MHz
Upstream: Sub-1GHz
Downstream: RS485
50Ω IPX connector
≤2300m
5VDC
≤0.3W
Special EPEVER transmission protocol
-20℃~70℃
two-year
4