- ページ 4
計測機器 Diehl Metering AURIGA DN 20のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Diehl Metering AURIGA DN 20 10 ページ。
AURIGA DN15/20
1.2.2
PRESSURE LOSS
1.3 TECHNICAL FEATURES
Body
Ring
Register
Modularity
Temperatures
Frost protection
Filtration
Clogging
Brass
Grey -> cold water
Glass in standard -> high resistance to moisture in extreme
environments (e.g. a manhole that is flooded on a regular basis).
Plastic in option
Waterproof -> the register withstands prolonged immersion.
Pre-equipped to be fitted (even on-site) with clip-on modules of the
IZAR range:
•
IZAR RC i – radio module
IZAR PULSE i – pulse emitter
•
IZAR MBUS COMPACT i – MBus emitter
•
IZAR DOSING – electronic register with reset
•
Water temperature: +0.1 ... +50°C (T50)
Operating ambient temperature: +1... +55°C max.
Storage temperature: -10 ...+55°C max.
Protect the meter from frost by completely draining all the water it
contains. Shut the valve upstream the meter and purge the circuit
(remove the non-return valve if necessary).
Caution: the pressure plate may break if the meter is not drained.
Plastic filter located in the inlet nozzle. The filter can be easily
checked and cleaned.
Caution: during normal operation, water going through the meter
must not contain any suspended solid particles larger than 0.1 mm
for a concentration of 0.1 gram/litre.
Withstands occasional sanding (i.e. following work carried out on a
pipe) without sustaining damage.
4