- ページ 23

顕微鏡 Olympus PROVIS AX70のPDF 概要をオンラインで閲覧またはダウンロードできます。Olympus PROVIS AX70 24 ページ。 Research system microscope

AX70 specifications
Item
Type
Y-shape frame with built-in transmitted/incident light vertical illuminator
Optical system
UIS optical system (infinity-corrected/compensation-free)
12V100W halogen (2,000 hours long-life type), pre centered
Mechanical field diaphragm (motorized field diaphragm unit attachable)
Transmitted illumination
Six built-in manual filters (ND1.5, ND3, ND6, ND12, IF550, LBD; motorized filter changer attachable)
One optional external filter can be user-installed (manual operation)
Universal vertical illuminator, 12V100W halogen/Hg100W/Xe75W applicable, optical devices detachable, motorized mirror unit changer, excitation light
Incident illumination
shutter (interlocking operation when changing an objective/observation method). Max. three filter sliders (six filters) attachable (when using AX-RFCH)
Illumination adjustment
1-12V (adjustable in units of 0.1V by the jog dial), light preset switch, transmitted/incident halogen illumination changeover switch
Vertical stage movement by manual roller guide, stage travel range: 25mm. Coaxial coarse and fine focus handle, minimum fine focus adjustment
Focus
graduation: 1 m increments, stroke per rotation: 0.1mm (fine), 15mm (coarse). Sensitivity: less than 1 m
Main switch located at power supply (U-PS), light adjustment dial: right front, field control knob: left front, sub-main switch, changeover switch for
Operation control position
transmitted/incident illumination, light preset switch: right wing of frame, hand switch attached (objectives direct changeover, objectives recall, mirror unit
direct changeover. Incident excitation shutter on/off, lamp off possible)
Power supply (U-PS)
100/120/220/230/240 V automatic changeover, main switch attached
(when using U-SWTR-2)
F.N. 26.5 (super widefield), adjustable
interpupillary distance range: 50-76mm,
Observation tube
inclined 24 , right eyepiece sleeve correction
mechanism, photo focusing can be attached,
reticle/photo mask rotation stop included,
(erect image, U-SWETR attachable)
Revolving nosepiece
Motorized sextuple nosepiece, motorized quintuple nosepiece for reflected darkfield observation, various manual nosepieces attachable
Stroke range: 52 76mm (with vernier), max two sliders can be inserted, torque adjustable, selectable from right handle or left handle, knob position (tip):
Stage
57mm from desk top
Vertical stroke range: 25mm (when using AX-UCDM: 10mm), centering adjustment function (AX-UCDM: standard feature), both sides condenser
Condenser holder
movement control knobs, (AX-UCDM: motorized)
Observation tube
Camera
Optical path changeover
Photo magnification
Zoom
Focusing telescope
Photo frame reticle
Shutter
Photometry
Photometry conditions
Camera back
Multi-control box
(U-MCB)
Auto focus
(on U-AFPHOTO only)
Eyepiece
10x, F.N. 26.5 (super widefield of view)
Conform to ISO (*1)
Objectives
Universal motorized condenser for AX (AX-UCDM): N.A. 0.16-0.9 (N.A. 0.16-1.4 with change of top lenses), objectives (1.25
diaphragm, top lens changeover polarizing plate attachment insertion: all motorized. Applicable for transmitted brightfield, transmitted darkfield, transmitted
phase-contrast, transmitted Nomarski DIC, transmitted simple polarizing observations.
Condensers
Swing-out Achromat (U-SC): N.A. 0.16-0.9, objectives (2 -100 ). Achromat/Aplanat (U-AAC): N.A. 1.4, objectives (10 -100 ). Universal (U-UCDB):
N.A. 0.2-0.9 , objectives (2 -100 ). Phase-contrast darkfield (U-PCD): N.A. 1.25, objectives (10 -100 ). For super low magnification (U-ULC-2): N.A.
0.16, objectives (1.25 -4 ). Darkfield (dry): N.A. 0.8-0.92, objectives (10 -40 ). Darkfield (oil): N.A. 1.20-1.40, objectives (10 -100 )
(*1) Conform to ISO9345-1, ISO8038.
AX70
F.N. 26.5 (super widefield), adjustable interpupillary distance range: 50-76mm, inclined 24 ,
magnification [(direct optical path: 1 , optical path through zoom: 1-2
Two 35mm cameras, one large-format camera, one video camera (all can be attached at the same
time); two video cameras can be mounted by connecting U-TVL to the large-format port; selectable by
U-MCB
U-PHOTO/U-AFPHOTO
[Direct optical path]
BI : video camera (direct) = 100:0/0:100
[Peripheral optical path] (all light goes to camera optical path during exposure)
BI : video camera (direct) : video camera 2 : photometry
= 100:0:0:0 / 0:100:0:0 / 0:0:100:0 / 20:0:0:80 / 0:20:0:80
(video camera 2 is mounted to the large-format port via U-TVL.)
When using auto focus function of U-AFPHOTO:
BI : video camera (direct) : video camera 2 : photometry : AF sensor
= 50:0:0:0:50 / 0:50:0:0:50 / 0:0:50:0:50 / 10:0:0:80:10 / 0:10:0:80:10
[Camera optical path]
35mm left : large-format : 35mm right = 100:0:0 / 0:100:0 / 0:0:10:0
When using video camera 2
35mm left : 35mm right = 100:0 / 0:100
U-PHOTO20/80
[Direct optical path]
BI : video camera (direct) = 100:0 / 0:100
[Peripheral optical path] (80% of all light goes to camera optical path during exposure)
BI : video camera (direct): video camera 2 : photometry
= 20:0:80:0 / 100:0:0:0 / 0:100:0:0 / 20:0:0:80 / 0:20:0:80
(video camera 2 is mounted to large-format port via U-TVL)
[Camera optical path]
35mm left : large-format : 35mm right = 100:0:0 / 0:100:0 / 0:0:100
When using video camera 2
35mm left : 35mm right = 100:0 / 0:100
35mm camera: 2.5x-5x, large-format camera: 7.5x-15x
Motorized control by jog dial or fixed magnification switch of U-MCB. Zoom ratio: 2
Manual insertion, magnification ratio: 3.4
Manual insertion, bright frame operation (red/yellow), illumination adjustment (seven levels)
Pulse-control electromagnetic shutter, shutter speed: max. 1/125 sec.
2D image analysis memory mode by the CCD. 0.1% spot measurement, 1% spot measurement, 30%
average measurement switchable. Flexible spot measurement area, spot color switchable (red/yellow)
Five exposure modes: Auto mode, FL Auto mode, Super FL Auto mode, Manual mode, time mode.
Auto exposure range: 1/125 sec.-68min. ISO: 3-25,600 (automatic setting by DX method, manual
setting also possible). 13-step exposure control (0.25-4, every 1/3 step). Auto bracketing function,
eight-level reciprocity failure correction, multi-exposure, AE lock, exposure time recall,, data/scale
imprinting function (by imprinting unit)
35mm (PM-C35DX): auto loading/wind/rewind and automatic film detection, data imprinting unit can be
attached, automatic setting of the ISO value by the DX code. Frame counting number is retained for
data back-up. Data imprinting unit (PM-DI-35): backlit exchange type
Large-format camera back (attached to U-DLF); Polaroid (PM-CP-3)
Operation by transmitted touch panel and jog dial sheet switch. Graphics indicated on plasma display.
Centralized control of mentioned photomicrography conditions and all motorized parts are possible.
Memory card function: can register, recall, delete, print the information of photometry and observation.
External interface function: selectable from RS232C, GPIB or printer interface (optional)
Optical path difference based contrast system. Operation modes: real-time mode and one-shot mode
(switchable). Applicable magnifications: 1.25 -100 . Applicable condensers: AX-UCDM, U-UCDB,
U-AAC, U-ULC-2. Applicable microscopic observation: brightfield/darkfield, Nomarski DIC, polarized
light (both transmitted and incident light), fluorescence (incident light only)
PLAPO set: PLAPO2
UPLAPO set: PLAPO2
UPLAPO4
UPLAPO10
UPLAPO20
PLAPO40
PLAPO100 O
AX70+U-PHOTO/U-PHOTO20/80/U-AFPHOTO
Integrated in photomicrographic unit
(besides U-AFPHOTO)
UPLAFL set: PLAPO2
UPLAPO4
UPLAFL4
UPLAPO10
UPLAFL10
UPLAPO20
UPLAFL20
UPLAPO40
UPLAFL40
UPLAPO100 O
UPLAFL100 O
(zoom)]
-100 ). Turret, aperture
22