USB Connectors
4.5

Install Focus EMO-SI Cable to DIN Panel

On systems with Focus stages, install the Focus EMO-SI cable running from the Focus MCU to the Din
Panel. Refer to SCHEM-0203A and LAYOUT-0100C in the wiring diagrams package.
First, install the provided wire labels (W2.9 for red, DC0V for black) and krimp the provided ring terminals
onto the two wires.
Next, install the cable into the Focus MCU. See figure 15.
Next, connect the wires on row 3 on the large electrical panel. See figure 16. The SI OUT TO FOCUS
MCU) W2.9 wire will be jumpered with W2.9 wires for MCU TT and MCU XY. The DC0V wire will be
jumpered with the other 2 DC0V wires.