バッテリーチャージャー AccuPower IQ216のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。AccuPower IQ216 9 ページ。

Figure 3: LCD after turning the charger on with no inserted batteries

Charging function:

The IQ216 has 16 independently monitored charging slots, where every four slots are sharing
their power. The display shows which slots belongs together. For this, every four battery symbols
on the display are coupled by a bar above that also shows if the slots are charging or
discharging. The discharge function is available only for the last four slots (13, 14, 15 and 16).
The charging current gets automatically set by the charger, depending on the battery size. This
feature should make the usage of the IQ216 much easier and much safer.
AA Size:
Because of their size, AA batteries can carry a higher charging current than the AAA batteries.
Therefore, the AA batteries are the only one, that could get charged with a current up to 1000mA
(max.) by the charger. The automatically chosen current is set by the IQ216 depending on how
many of the by-four-paired slots are occupied. If one or two slots of a foursome are used by AA
sized batteries, then the current is set to 1000mA (max.).
On the other hand, if three or all four slots get occupied by AA batteries, the charging current gets
lowered to 500mA (max.)
INFORMATION: Please note, that every by-four-paired slots (e.g. slot 1, 2, 3 and 4) are working
independently from the other three foursomes. A lowered current for the first four slots, doesn't
mean that other slots from a different foursome can provide a high current.
After inserting a battery in a slot, the backlight of the LCD lights up for approx. 30s and confirms
that the inserted battery is detected by the charger. With the help of the triangle shaped bars you
can see if the charger has chosen 1000mA (max.) or 500mA (max.) for your battery / batteries.
If only the left-hand bars are going up, then the battery gets charged with a lower current.
Otherwise the charger has set the higher current for the respective slot, apparent when not only
the left-hand bars, but also the right-hand bars are visible.
During the charging process, the bars that stays stable are a reference for the state of charge for
the respective battery.
Figure 4:Double-sided triangles
-higher charging current
AAA Size:
User Manual
„Battery Full"
4/9
English
Left-hand sided triangles
- lower charging current