- ページ 2
配管製品 Axor One 48792003のPDF 使用説明書/組み立て説明書をオンラインで閲覧またはダウンロードできます。Axor One 48792003 12 ページ。
0 2
EN
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and/or
sensoric impairments must not use this product without
proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
⁄ During installation of the product by qualified trained
personnel, make sure that the entire fastening surface is
even and smooth (no protruding seams or tile offset),
that the finish of the wall is suitable to apply the product
and has no weak points.
⁄ With the excentric washer it is possible to equalize
tolerance of the drilling. (see page 06)
⁄ The premounted filter insert must be used to ensure a
normal flow of the shower and to prevent dirt from
entering through the pipes. Dirt entering can affect the
function and/or lead to damages to the shower.
Hansgrohe will not be held liable for this type of
damage.
⁄ Optimal functioning is only guaranteed with the
combination of Hansgrohe hand showers and
Hansgrohe shower hoses.
⁄ The installation must be compliant with the AS 3500.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
A S S E M B L Y (see page 05)
max. 0,6 MPa
0,15 - 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
D I M E N S I O N S (see page 04)
S P A R E P A R T S (see page 09)
XX = Colors
00 = Chrome Plated
67 = Matt Black
S P E C I A L A C C E S S O R I E S
(order as an extra)
⁄ tile-matching-disk #96397XX0 (see page 09)
C L E A N I N G (see page 08)
O P E R A T I O N (see page 08)
M A I N T E N A N C E
⁄ The check valves must be checked regularly
according to EN 806-5 in accordance with
national or regional regulations (at least once
a year).