- ページ 6

アダプター ACCUR BA-100のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。ACCUR BA-100 8 ページ。

2、Time delay:40ns
3、SDI signal Eye Diagram testing and signal quality characteristic
parameter
Interface
Video format
Amplitude(mv)
Over/Undershoot
Rise/Fall
Time
Timing jitter
(10Hz)
Alignment jitter
SD(1KHz)
HD(100kHz)
3G(100kHz)
SDI digital signal quality characteristic parameter(testing)
NOTE: the above technical parameter are all real testing value, but the relating data testing
can be affected by testing environment , SDI cable quality , transmission distance, maching
impedance, BNC connector.,etc , thereby , the related technical parameters will be subject
to the actual testing data based on customer ' s use environment.
576 50i
1080 60p
SD-SDI
801
0%/0%
678ps/
649ps
0.09UI
0.06UI
1080 50i
Note : Eye diagram testing use the
SDI cable from Canare L-3C2VS,
length is 300mm.
SDI-OUT
HD-SDI
783
0.6%/0%
85ps/
83ps
0.22UI
0.05UI
3G-SDI
786
1.2%/0.6%
94ps/
90ps
0.48UI
0.11UI