- ページ 3

扇風機 Cinier GreenorのPDF 取付方法をオンラインで閲覧またはダウンロードできます。Cinier Greenor 9 ページ。 Fan coil

Cinier Greenor 取付方法
Greenor
H
®

HEATING SYSTEM

To operate in heating system only mode
To operate with a conventional boiler on a closed
hot water circuit with a maximal service-pressure
101.5 PSI/7bars and a maximal water temperature
of 167°F / 75°C.
Getting ready to connect the heatin
(drawing No 1)
Prepare the supply and return water inlets
(elbow fittings males 1/2" flat gasket); Respect the inlet /outlet flow as per drawing.
Prepare the power cable as shown on
drawing No 1.
The power supply cable should project out of the wall by about 11"/ 30cm.
Greenor
R
®
REVERSIBLE HEATING AND COOLING SYSTEM
To operate in reversible mode
To use with a reversible heat pump on a closed
water circuit with a maximal service pressure 101.5
PSI / 7bars and a maximal water temperature of
167°F / 75°C and minimal water temperature of
44.6°F/ 7°C
Getting ready to connect the reversible system
(drawing No 2)
Prepare the supply and return water inlets
(elbow fittings males 1/2" flat gasket); Respect the
inlet /outlet flow as per drawing.
Prepare the power cable as shown on drawing No 2.
The power supply cable should project out of the wall by about 11"/ 30cm.
Besides,
it
is
necessary
indirect waste pipe, to dispose of condensate into the waste water circuit.
An optional pump is available, in that case plan a
pipe 0.24"x0.31"/ 6x8mm with a length of about
1"/ 30mm for the evacuation.
ONLY
g system
only
to
plan
drainage
Details of hydronic connections
Drawing No 1 -
Details of hydronic connections
Drawing No 2 -
of condensate using a drain and an