Warning

The following warnings must be exactingly observed:
Failure to comply with the warnings may result in fire, property
damage, electric shock, injury, or death.
To prevent suffocation, electric shock, injury or death, the customer
is responsible to ensure that children shall NOT access the product.
The product shall not be modified, disassembled or serviced.
The product shall be shut down if the outdoor air temperature
exceeds 35ºC or 95ºF.
The vents (A and C) of the product shall NOT be blocked at all.
The enclosure shall not be opened when the product is powered.
NOTE 
The manufacturer
supplies third-party
The electrical parts of the product shall not be touched even if the product
locks that the customer
has been shut down. The electrical parts are the fans (F and G),
may install to shut the
power bar (I), and supply fan controller (J).
door of the enclosure.
As soon as possible, the power supply cord (E) shall be safely
disconnected from the wall power or electrical mains if liquid spills on or
around the product.
The power bar (I) shall only be connected to an electrical receptacle that is
permanently installed in a building.
The power bar (I) shall not be connected to a relocatable power tap.
There shall be no connection of any external devices to the power bar (I).
The cables of the fans (F and G) shall not be disconnected from the
power bar (I).
NOTE 
The supply fan controller (J) may not be arbitrarily adjusted in order not to
disrupt the calibration of the product.
An indicator is affixed
to the supply fan
controller (J) on a
parallel axis to the
nominal position of the
controller knob.
3

Installation

The following points shall be strictly observed when installing the product:
The product shall not be installed near hazardous or toxic materials.
NOTE 
The product shall not be
installed at a location
The product shall only be installed in either vertical or horizontal
where there is probable
orientations and shall not be positioned at an oblique angle.
contact with liquids.
For vertical orientation, the supply vent (A) shall face upwards as
NOTE 
indicated in Figure 1(a). There is no restriction on the horizontal
The product shall be
orientation of the product provided the exhaust vent (C), exhaust
carefully positioned
duct (D), and power supply cord (E) are not obstructed.
such that it may not trip
and cause property
damage or bodily injury.
The product may be placed on the floor or a sturdy table.
Professional help may be needed to install the product on a wall.
NOTE 
The product shall not be
The vents (A and C) and ducts (B and D) shall NOT be connected
installed at a location
to external appliances such as dryers, fans, furnaces, etc.
where there is excessive
heat or exposure to
direct sunlight.
The product shall be installed in the conditioned space of a building where
the temperature and relative humidity of air are within the range of
NOTE 
22ºC – 24ºC and 35% – 50%, respectively.
The ports of the
ventilation kit shall be
The product shall not be powered until the ducts (B and D) are installed.
4 in (~10.2 cm).
A ventilation kit (not bundled with the product) is needed to install the two
NOTE 
ducts (B and D) such that air can securely and simultaneously be supplied
The product is designed
to and expelled from the building space.
to deliver air at a flow
rate of 10 – 20 CFM.
The product shall not be
The ventilation kit can interface with the outdoors though a window, door
operated outside of this
or wall as illustrated in Figure 3. The customer is responsible for
prescribed range.
complying with all applicable codes and regulations.
To power the product, connect the plug of the power supply cord (E) to
the wall power (~120V AC, ~60Hz). To shut down the product,
disconnect the power supply cord (E) from the wall power.
4