- ページ 3

バスルーム設備 Axor Starck Nature 240 1 jet 12670 7 SeriesのPDF 使用説明書/組み立て説明書をオンラインで閲覧またはダウンロードできます。Axor Starck Nature 240 1 jet 12670 7 Series 16 ページ。

S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
Children as well as adults with physical, mental and ⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ If there is a risk of frost: In order to protect the showerpipe from damage caused by
frost, the lines have to be laid in such a way that they can be emptied up to the
frost-free area.
⁄ During winter storage: The product have to be completely dismantled and stored in
a dry place. All components must no longer contain water.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The product is not designed to be used with steam baths!
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ The mesh washer must be insert to protect the shower against incoming dirt by
pipework. Incoming dirt leads to defects or⁄and can damage parts of the shower;
such caused faults voids all liability and guarantee claims.
⁄ The arm of the shower head is intended only to hold the shower head. Do not load
it down with other objects!
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Centre distance:
Connections G 1⁄2:
Thermal disinfection:
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
F A U L T
⁄ Insufficient water
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Instantaneous heater didn't work with thermostat
A S S E M B L Y (see page 04)
S Y M B O L D E S C R I P T I O N
i
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
150±12 mm
cold right - hot left
70°C ⁄ 4 min
C A U S E
⁄ Supply pressure inadequate
⁄ Regulator filter dirty
⁄ Shower filter seal dirty
⁄ Backflow preventers dirty or leaking
⁄ Filters are dirty
⁄ check valve hasn't moved back
⁄ Flow limiter in handshower isn't removed
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 05)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
M A I N T E N A N C E (see page 05)
⁄ The check valves must be checked regularly according to EN 806-5 in
accordance with national or regional regulations (at least once a year).
⁄ To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
D I M E N S I O N S (see page 10)
F L O W D I A G R A M (see page 10)
S P A R E P A R T S (see page 15)
XX = Colors
34 = Brushed Black Chrome
67 = Matt Black
S P E C I A L A C C E S S O R I E S (order as an extra)
extension 80 mm #13608000 (see page 15)
cover #12675000 (see page 15)
I N S T A L L A T I O N E X A M P L E (see page 14)
C L E A N I N G (see page 12)
D I S M O U N T I N G
If there is a risk of frost (see page 06)
During winter storage (see page 07)
R E T U R N T O S E R V I C E
When there is no more a risk of frost (see page 08)
After winter storage (see page 09)
O P E R A T I O N (see page 11)
To empty the overhead shower after use, hold it in a slightly inclined position.
R E M E D Y
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Clean filter in front of the mixer and on the MTC-thermo
cartridge
⁄ Clean filter seal between shower and hose
⁄ Clean backflow preventers, exchange if necessary
⁄ Clean the filter ⁄ exchange filter
⁄ Exchange check valves
⁄ Remove flow limiter
0 3
EN