In order for you to be able to install your Cintroclear purifier very quickly and simply, the unit is fitted entirely
with automatic connectors. These special connectors allow all the purifier pipework and accessories to be
connected without using any tools. They are particularly easy to use, they can be fitted in a few seconds
and they are completely reliable.
PLEASE NOTE : To cut the pipes you may only use a snap-off knife with a new blade. Cut the pipe off on a
softwood board. The cut must be straight, neat and free of burrs. Never use a kitchen knife, scissors or
wire-cutters. If so, the cut edge will not be even and you run the risk of damaging the O ring when you slide the
pipe into the coupling or that leaks occur.
O-ring seal
Use of instantaneous automatic connectors
Locking ring
Stop
Cut ...
Pusch ...
Finished !
CONNECTING :
Position the pipe in the connector and push it right
home. The depth of penetration is approximately 16
mm.
Once the pipe is right home, the stainless steel teeth
hold it in position and the O-ring seal ensures a
perfect seal. The connection is definitive, no further
operation is required.
VERIFICATION :
Pull gently on the pipe to check that it is held
correctly in position.
DISCONNECTING :
To disconnect the pipe, push the ring right in on
the connector (red arrows) and pull the pipe out
while still pressing the ring in. Disconnection may
be carried out several times without harming the
pipe. Before each disconnection, check that the
pipe is not under pressure.