- ページ 3

キーパッド Digicode DGAのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Digicode DGA 20 ページ。 Surface-mount keypad - cast aluminium

INSTALLATION MANUAL
DGA
Cast aluminium Digicode

AUDIBLE SIGNAL

- 1 short beep
>
- 1 long beep
>
- 2 short beeps
>
- 4 short beeps
>
CODE LENGTH
- All the keypad keys can be used to program a code,
- The master code and the Pin code can be of 4, 5 or 6-digits,
- The master code CAN NOT be used as a PIN code (User Pin code),
- Codes 000000, 00000 and 0000 can only be used to delete a user code,
- To delete a specific User Code replace it by 0000 if code length is 4-digit format or replace it
by 00000 if the code is in 5-digit format.

REQUEST-TO-EXIT INPUT

P1 input activates relay 1. (The output can be programmed) :
- The timer input H1 if connected allows using the 0 key as a request-to-enter,
- If the timer contact is open then the 0 digit key is used for the Pin code,
- if the contact is closed then the 0 key is used for the request-to-enter.
CONSUMPTION
- 12V AC: in stand-by 20 mA, when 2 relay outputs activated 80 mA max,
- 24V AC: in stand-by 10 mA, when 2 relay outputs activated 40 mA max.
RESET MASTER CODE AND DELETE ALL USER CODES
1] Enter the master code twice (12345 default value master code):
- the red LED lights on to confirm entry in programming mode.
2] Press A6 to enter in the reset menu:
- the green LED lights on for 1 second,
- press simultaneously on A and B to start the reset,
- the green LED lights during all the reset process, wait until it lights off,
- the master code is reset to its factory value 12345 and all the user codes are deleted,
- the keypad is reset to the factory default values, the red LED lights on then lights off.
------------------------------------------------------ OR ---------------------------------------------------------
1] Turn off the power. Short the white and the yellow wires.
2] Power on the keypad:
- the green LED lights on,
- wait a few seconds, one beep is emitted. The green LED lights off. Unshort the wires.
3] The keypad is reset to the factory default values.
SETTING CODE LENGTH
1] Enter the master code twice (12345 default value master code) :
- the red LED lights on to confirm entry in programming mode
2] Press A4 to program the code length:
- the green LED lights on during 1 second,
- press 4, 5 or 6 to enter the code length,
Self Contained
®
Keypad powered,
data computing in programming or access granted,
Enter or Exit from programming,
Data computing error.
EN
cdvi.se
3
cdvigroup.com