Custom Mode 6: Generic three-output delay/pulse width,
level driven (validity)
Description: When either input goes active, each output will go active after a
delay, and then stay active for a pulse width. Each output has an independent
delay and pulse width, definable between .1 and 300 seconds.
Connections:
Interface wiring
Pin 2 (Purple)
Pin 3 (White)
Pin 4 (Pink)
Pin 5 (Orange)
Pin 6 (Green)
Pin 7 (Red)
Pin 8 (Blue)
Pin 9 (Brown)
Pin 10 (Gray)
To
Ground
Ground
Ground
Ground
Negative output (500 mA max)
Negative output (500 mA max)
Positive output (2 amp max)
Positive pulse input (use only one)
Negative pulse input (use only one)