- ページ 2

屋外ライト CREE LIGHTING EDGE XBPのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。CREE LIGHTING EDGE XBP 6 ページ。 Led pathway

STEP 7:
Pull wire up through pole and then reattach
pole to base with the three ¼-20 flat head
screws removed in step 1.
STEP 8:
Slide Dome Cover over pole. Align counter bore
hole in Dome Cover with hole in "L" bracket and
secure with one ¼-20 x 0.625 flat head screw.
STEP 9:
Make electrical connections per the electrical
section.
STEP 10:
Reposition optical assembly onto pole and
secure by torqing the 3/8-16 pan head screw to
240 in lb. See Figure 5.
ELECTRICAL CONNECTIONS
PHASE TO NEUTRAL WIRING
CAUTION: Verify that the power is turned off before proceeding.
STEP 1:
Make the following Electrical Connections to the terminal block:
a. Insert supply circuit ground conduct into terminal block by
depressing the terminal block button next to the factory installed
green wire.
b. Insert supply circuit line conduct into terminal block by depressing
the terminal block button next to the factory installed black wire.
c. Insert supply circuit neutral conduct into terminal block by
depressing the terminal block button next to the factory installed
white wire.
NOTE: Verify voltage before applying power to bollard.
2 of 3
5
DIRECT CONCRETE MOUNT
STEP 1:
Follow Step 1 and Step 2 from "INSTALL
PATHWAY" directions above.
STEP 2:
Position concrete inserts in concrete at three
bolt hole positions illustrated in Figure 7 below.
STEP 3:
Position steel base plate over inserts and
secure with three 3/8-16 screws.
STEP 4:
If using decorative dome cover, attach L
bracket to hole in transition plate using #8 x
0.25 screw.
STEP 5:
Loosen 3/8-16 pan head screw located at the
arm base of optic assembly using a T-45 torx
socket and ratchet.
See Figure 4.
STEP 6:
Lift optic assembly from pole.
STEP 7:
Pull wire up through pole and then reattach
pole to base with the three ¼-20 flat head
screws removed in step 1.
STEP 8:
If using decorative dome cover, slide it over the
pole. Align counter bore hole in Dome Cover
with hole in "L" bracket and secure with one
¼-20 x 0.625 flat head screw.
STEP 9:
Make electrical connections per the electrical
section.
STEP 10:
Reposition optical assembly onto pole and
secure by torqing the 3/8-16 pan head screw to
240 in lb. See Figure 5.
CI347X02R1_B