Technical data
Manufacturer
Address
Article number/Ordering data
Power supply
Operating voltage
(to Vital, A1-A2)
Power supply to sensors/units
(from Vital, B1-B2)
Power consumption
Reset input X1
(see section Reset connections above)
Max line resistance
External fuse
Relay outputs
NO
Max switching capacity
Minimum load
Contact material
Mechanical life
External fuse (EN 60947-5-1)
Conditional short-circuit current (1 kA)
Relay information output, Y14
(changeover contact)
General
Protection class
Ambient temperature
Humidity range
Rated insulation voltage
Rated impulse withstand voltage
Pollution degree
2TLC172156M0201, rev. C
2016-07-04
ABB JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
Vital 1, ver. H (from 2011): 2TLA020052R1000
24 VDC +15%, -15% (SELV/PELV)
24 VDC nominal (depending on supply to A1-A2)
Current limit: 1.8 A
Nominal, without load (min): 3 W
Nominal, with load (max): 48 W
Supply for reset input: +24 VDC
Reset current: 30 mA (inrush current 300 mA)
Minimum contact closure time for reset: 150 ms
150 Ω (at nominal voltage over X1)
3 A (an external fuse should be fitted in the supply to A1)
2
Resistive load AC: 6 A / 250 VAC / 1500 VA
Inductive load AC: AC15 240 VAC, 2 A
Resistive load DC: 6 A / 24 VDC / 150 W
Inductive load DC: DC13 24 VDC, 1 A
10 mA / 10 V
AgCdO
7
> 10
operations
5A gL/gG
6A gL/gG
Max load: 200 mA (internal automatic fuse)
See section Output connections for functionality.
Enclosure: IP40
Connection blocks: IP20
Storage/Operation: -10...+55°C
35 to 85 % (with no icing or condensation)
250V
2.5kV
2
17
www.abb.com/jokabsafety