USING THE CONCRETE CORING
ATTACHMENT
13. Assemble the Coring Unit by attaching
the Concrete Coring Bit via the threaded
1-1/4" UNC connection.
15. Fill a container with water to use as a
flushing medium and suspend this above
the height of the Coring Unit
14. Attach the Coring Unit onto the rig at
the base of the anvil. Connect the
hydraulic hoses leading from the Right-
Hand side of the control block onto the
snap-on couplings of the Coring Unit.
(these hoses may first need to be
disconnected from the chain motor).
16. Siphon the water from the container
through a hose and attach this to the hose
spigot on the Coring Unit. The flush must
be maintained continuously when coring.