Display for linear measurement
Count direction
Set out the count direction of the display, range allowed 0 or 1.
Setting 0 the value on the display increases, turning the hollow shaft clockwise.
Setting 1 the value on the display decreases, turning the hollow shaft clockwise.
Keys opening mode
This parameter programmes the functions linked to the keys.
The value to set is a number of three digits so each key corresponds to a digit; the digit on the right stands for
setting of key
, the digit in the middle stands for key
RESET
The values allowed are the following:
VALUE
KEY
0
Not open
1
Function
2
Not open
3
Not open
4
Not open
Reset: function of reset of quota, pressing on key
Preset: function of preset of quota, pressing on key
one set in parameter Preset. The setting of Preset value appears immediately after parameter
chose value 2).
Fast Preset: the fast setting of the quota on the display, pressing on key
still 2 times
is possible to set the value directly (use keys
RESET
function is useful when the quote on the display has often be corrected.
Origin change (quota correction for tool change): with this function 3 different origins (0,1,2) are
programmable and passes from an origin to the other wit key
on the display appear two small arrows and the indication of the selected origin happens with the switching
on of the origin indicators (see paragraph meaning of symbols ). After setting 4 in the first digit on the right of
, will appear PrS0 and pressing 2 times
shaft for origin 0, confirm with
present position of shaft: set the correct value and confirm with
to be read for origin 2 in the present position of shaft: set the correct value and confirm with
PrS0, PrS1, PrS2 are references for the calibration, in a certain position of the shaft, in three different origins.
Function
/
: Enables the pass from absolute to relative value, pressing key
ABS
REL
value to allow a relative shifting. On the display switches on indicator REL to indicate that the current quote is
relative to the zero-point just created. Pressing still key
switches on the indicator ABS.
Conversion mm/inch: Pressing key
indication of inch/mm on the display and a decimal number more then for millimetres. By choosing 5
decimals for millimetres the conversion in inches is not allowed.
Visualization in degrees: Pressing on key
measure in degrees.
Origin displacement
This parameter is added or subtracted from the current quota to correct the value showed on the display, for
example following wear or changing of tool. Setting a positive value on display appears the current quota added
to this value.
Set zero to exclude the offset function (manufacturer's value).
The offset is not available if the function of tool-change is selected.
Data: 13/01/16
/
Conversion mm/inch
ABS
REL
Display in degrees
RESET
RESET
. It will appear PrS1 which is the value to be read for origin 1 in the
RESET
converts the measure from millimetre to inches and back with
on the display appears Deg to indicate the visualization of
file: Simplex_ing.doc
while the last digit on the left stand for key
KEY
Not open
Not open
Not open
the quota is zero-set .
the quota on the display became the same of the
RESET
RESET
. Activating the function of origin change
RESET
has to be set the value to be read in this position of
. It will appears PrS2 which is the value
RESET
reappears the absolute value and on the display
SIMPLEX-E
KEY
RESET
Not open
Reset
Preset
Fast Preset
Change of origin 0,1,2
appears Preset and pressing
and confirm with
RESET
. It means
RESET
zero-set temporary the
.
(if
). This
pag 4/8