Setup
Locks are shipped with factory default settings (only operates by pressing `). Each lock must be set up to operate with a Programming
Key and Manager Keys.
1
Insert the Programming Key.
A two-tone beep will be heard
and the LED will fl ash.
Programming Instructions
Express Register Manager Keys
The Programming Key can quickly program multiple locks to operate with the same Manager Keys.
1
Go to a lock already programmed to operate with the Manager Keys.
Touch and hold
`
for 10 seconds (a two-tone beep will be heard after
5 seconds followed by 2 sets of two-tone beeps after 10 seconds)
then release.
The LED will flash.
3
At each lock to be programmed, insert the Programming Key.
A two-tone beep will be heard and the LED will fl ash once to indicate
successful registration.
*The Programming Key will continue to function in Express Registration mode until it is used to operate a lock.
Product Guide
2
While the LED is fl ashing, insert
one Manager Key at a time.
A two-tone beep will be heard for
each Manager Key programmed.
Touch RFID
Key Managed
Shared Use Functionality
3
While the LED is fl ashing, insert
the Programming Key.
A two-tone beep will be heard
and the LED will turn off.
2
While the LED is fl ashing, insert the Programming Key.
A two-tone beep will be heard and the LED will turn off.
4
To end Express Registration mode:*
Go to any programmed lock.
Press
then insert the Programming Key.
`
4
Repeat above steps for each lock
or follow instructions to Express
Register Manager Keys to setup
all locks.