Inputs description
The positioner is controlled by 4 optoinsulated inputs that are:
START:
active from open to close; it starts the positioning;
EMERGENCY: it must usually be closed; if it is open, it stops the positioning;
WORK COUNTER:
from closed to open of the work counter input in order to carry on the subsequent positioning;
RESET:
active from closed to open; it determines the resetting/presetting of the dimension or the zero
research.
For the relevant connections see wiring diagram on page 10
Outputs description
The positioner can manage the following outputs:
STOP/ONWARD/BACKWARD: it controls the speed and the motion direction of the positioned axis,
END OF POSITIONING:
AUXILIARY OUTPUT(AUX):
ANALOGUE OUTPUTS
For the relevant connections see wiring diagram on page 10
Description of the front panel
The display1 always displays the axis dimension, whereas the other displays show different parameters as a
function of the positioner status.
The function indicators show the currently selected function.
DISPLAY 1
DISPLAY 2
DISPLAY 3
DISPLAY 4
INDICATORI
FUNZIONE
PROGRAMMING
The keys used for programming are the following:
P
Function choice programming
E
Enter to confirm the entered values
C
Clear to cancel/enter values
Increment or start key(only in the automatic/semiautomatic function)
START -
STOP +
Decrement or stop key (only in the automatic/semiautomatic function)
The programming and the use of the positioner is based on 8 main functions the selection of which is obtained
by pressing the P key followed by the relevant numerical key. The default function present when the tool is
switched on is the automatic/semiautomatic function (A/S); when the P key is pressed, the
display the
writing (function choice) followed by the numerical key corresponding to the wished
data: 13/01/16
work counter input; at the end of every positioning the instrument waits for a switchover
contact that closes at the end of positioning,
programmable auxiliary contact (end of cycle, work number, etc),
in current 4/20mA and in voltage, set-up between 0/10V and -10/10V.
5
PROG
COST
MAN
ZERO
1
START
STOP
-
file: P1X_T_ing.doc
7
<<
4
<
6
8
7
1
TEST
CYCL
SING
A/S
2
3
4
P
E
C
+
8
9
>>
5
6
>
2
3
.
0
DISPLAY
pag 2 di 11
will
2