: to reduce the error made by truncating the digits after the radix point in the value to be displayed, it
NOTE
is advisable to multiply
number of significant digits; with the above mentioned values by multiplying everything by 100 it is
possible to obtain
for
.
15) Number of decimals
It sets the number of decimals of the display that can be set between 0 to 5.
16) Preset dimension
Value of the dimension that will be displayed by using the zero setting function or by enabling the
input in the terminal box according to what was set in the following constant.
17) Zero setting mode
The setting of the zero setting mode enables to select the effect of the E key or of the
according to the following table:
0
1
2
3
4
5
6
7
8
9
10
Modes 9 and 10 refer to the zero research automatic cycle (see on page 3) the zero setting/presetting or
zero research function).
Zero automatic research mode1
In the automatic zero setting function when the
axis is started searching for the zero input. When the zero point is reached the axis motion continues for
2 seconds more and then stops and carries out the dimension presetting.
Zero automatic research mode 2
In the automatic zero setting function when pressing the
is started searching for the zero input. When the zero point is reached the axis is stopped and the
dimension presetting is carried out.
18) Dimensions protected by password
In order to prevent the accidental or unintentional alteration of the positioning dimensions, the instrument
gives the opportunity to protect with a password the access to the dimensions. It is thus possible to select
between 0 , dimensions protected by password, and 1 ,dimensions unprotected by password.
19) Time constant for acceleration ramp
Starting the positioning axis, before reaching the maximum speed, the positioner produces an
acceleration ramp with a time constant that may be set-up between 50 to 9999 milliseconds.
20) Time constant for deceleration ramp
During the positiong, reached the Slow value, by the passing from the speed Fast to the speed Slow, it
produces a decelaration ramp with a time constant that may be set-up between 50 and 9999 milliseconds.
data: 13/01/16
and
by 10 or 100 or 1000 in order to consider the maximum
=123456 and
=10000 by thus obtaining 6 significant digits (instead of 4)
E
KEY
DISABLED
DISABLED
RESET
PRESET
RESET
PRESET
RESET
PRESET
DISABLED
DISABLED
DISABLED
START
file: P1X_T_ing.doc
RESET
RESET
PRESET
RESET
RESET
PRESET
PRESET
DISABLED
DISABLED
DISABLED
PRESET in zero automatic
research mode 1
PRESET in zero automatic
research mode 2
- key is pressed the slow backward motion of the
- key the slow backward motion of the axis
START
PRESET
input
PRESET
INPUT
pag 7 di 11