- ページ 16
防犯カメラ Digimerge DPD24WのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Digimerge DPD24W 18 ページ。 Ultra resolution tdn wdr varifocal dome
¡á Troubleshooting
If you have trouble operating your camera, refer to the following table.
If the guidelines do not enable you to solve the problem, contact an
authorized technician.
Problem
Nothing appears on
• Check the power connections.
the screen.
• Check the VIDEO signal line connection.
The image on the
• Make sure the lens is clean. Clean the lens with a
screen is dim.
soft clean lint free cloth.
• Adjust the monitor contrast & brightness controls.
• Re-position the camera if necessary.
The image on the
• Adjust the contrast control of the monitor.
screen is dark.
• If you have an intermediate device, set the 75§Ù/ Hi-z
properly.
The camera is not working
• Check that an appropriate power source is
properly, and the surface
connected to the camera.
of the camera is hot.
The Motion Detection
• Check that MOTION DET in the SPECIAL SETUP
is not set to 'OFF'.
function does not
work.
Ultra Resolution TDN WDR Varifocal Dome
Solution
28
Problem
Color is not correct.
• Check the WHITE BAL settings in the SETUP menu.
The screen flickers
• Check that the camera is not facing toward the
sun.
continually.
RS-485
• Check the polarity between the RS-485 Control Port
and the RS-485 cable.
communication fails.
485 Control Board Connection Port
(+) CONNECTION TERMINAL (TRX+)
(-) CONNECTION TERMINAL (TRX-)
• Check the RS-485 Communication default settings.
* RS-485 Communication default settings are:
Item
Initial value
29
Solution
RS-485 Control Port
485+
485-
Camera ID
BAUD RATE
1
2400
Ultra Resolution TDN WDR Varifocal Dome