キーパッド Digiplex DGP-641ACCのPDF プログラミング・マニュアルをオンラインで閲覧またはダウンロードできます。Digiplex DGP-641ACC 2 ページ。 Access control lcd keypad
Digiplex DGP-641ACC にも: プログラミング・マニュアル (2 ページ)

Access Control LCD Keypad V1.0
DGP-641ACC
Programming Guide
P
M
ROGRAMMING
ETHOD
STEP 1: Press and hold the [0] key
STEP 2: Enter the [
INSTALLER CODE
STEP 3: Enter section [953]
STEP 4: Enter the keypad's 8-digit [
STEP 5: Enter the 3-digit [
STEP 6: Enter the required data
To view the keypad's serial number, press and hold the [0] key,
then enter the [
INSTALLER CODE
that you use this sheet to keep track of which sections were
programmed and how. This module can also be programmed using
the control panel's Broadcast Programming Feature (see Digiplex
Installation & Reference Manual).
P
S
ROGRAMMING
ECTIONS
In the following tables and sections, any value represented in bold
is the default setting.
SECTION [001]: Partitioning
Option
[1]
Partition 1
[2]
Partition 2
[3]
Partition 3
[4]
Partition 4
[5]
Assign Door to Partition 1
[6]
Assign Door to Partition 2
[7]
Assign Door to Partition 3
[8]
Assign Door to Partition 4
SECTION [002]: General Options
Option
[1]
Display Code Entry
[2]
Display Exit Delay
[3]
Display Entry Delay
[4]
Confidential Mode
(not for UL installations)
[5]
To Exit Confidential Mode
[6]
Reader's red LED to follow
Partition's status
[7]
Reader's beeping to follow
Partition's status when [6] ON
[8]
Not used
]
]
SERIAL NUMBER
] you want to program
SECTION
] and enter [000]. We recommend
OFF
ON
l Disabled
l Enabled
l Disabled
l Enabled
l Disabled
l Enabled
l Disabled
l Enabled
l Disabled
l Enabled
l Disabled
l Enabled
l Disabled
l Enabled
l Disabled
l Enabled
OFF
ON
l Disabled
l Enabled
l Disabled
l Enabled
l Disabled
l Enabled
l Disabled
l Enabled
l Enter Code
l Press Button
l Disabled
l Enabled
l Disabled
l Enabled
l N/A
l N/A
SECTION [003]: General Options
Option
[1]
Muting
[2]
Exit Delay Beep
[3]
"Door Left Open" Pre-Alarm
[4]
Chimed Zone Closure
[5]
"Door Left Open" Alarm
"Door Left Open" Alarm follows l Alarm Restore l Beep Timer
[6]
[7]
"Door Forced" Alarm
[8]
"Door Forced" Alarm follows
SECTION [004]: Beep on Trouble
Option
System & Clock Trouble Beep l Disabled
[1]
Communicator Trouble Beep l Disabled
[2]
Module & Bus Trouble Beep l Disabled
[3]
[4]
All Zone Trouble Beeps
[5] to [8]Not used
SECTION [005]:
General Options
Option
[1]
Card Activates Door
Unlocked Schedule
[2]
Not used
[3]
Not used
[4]
Not used
[5]
Keypad Tamper
[6]
Door will Relock
[7]
Reader's Green LED for
Access Granted
Door Handle Option for REX l Turn Handle
[8]
SECTION [006]
"Door Unlocked Period" (001-255 seconds)
___/___/___ (default = 005)
SECTION [007]
"Door Unlocked Period Extension" (001-255 seconds added to [007])
___/___/___ (default = 015)
SECTION [008]
"Door Left Open" Interval (001-255 seconds)
___/___/___ (default = 060)
SECTION [009]
"Door Left Open" Pre-Alarm Timer (001-255 seconds)
Time to start Pre-Alarm before alarm is triggered.
___/___/___ (default = 015)
SECTION [010]
Beep Timer for "Door Left Open" Alarm (001-255 seconds)
Amount of time "Door Left Open" alarm will beep.
___/___/___ (default = 005)
SECTION [011]
Beep Timer for "Door Forced Open" Alarm (001-255 seconds)
Amount of time "Door Forced Open" alarm will beep.
___/___/___ (default = 005)
SECTION [012]: Door Unlocked Schedule
Start time
End time
A:
___ ___:___ ___ ___ ___:___ ___ 1 2 3 4 5 6 7 8
B:
___ ___:___ ___ ___ ___:___ ___ 1 2 3 4 5 6 7 8
OFF
ON
l Disabled
l Enabled
l Disabled
l Enabled
l Disabled
l Enabled
l Disabled
l Enabled
l Silent
l Audible
l Silent
l Audible
l Alarm Restore l Beep Timer
OFF
ON
l Enabled
l Enabled
l Enabled
l Disabled
l Enabled
l N/A
l N/A
OFF
ON
l Disabled
l Enabled
l N/A
l N/A
l N/A
l N/A
l N/A
l N/A
l Disabled
l Enabled
l Immediately
l When closed
l Disabled
l Enabled
l Push Open
Days
(turn
or
)
ON
OFF
S M T W T F S H