- ページ 21

スイッチ Cisco AP776A - Nexus Converged Network Switch 5020のPDF リリースノートをオンラインで閲覧またはダウンロードできます。Cisco AP776A - Nexus Converged Network Switch 5020 22 ページ。 Cisco nexus 5000 series release notes release 4.1(3)n1(1) (ol-16601-01 h0, july 2009)
Cisco AP776A - Nexus Converged Network Switch 5020 にも: リリースノート (48 ページ), リリースノート (44 ページ), リリースノート (26 ページ), クイック・リファレンス・マニュアル (14 ページ), リリースノート (3 ページ), リリースノート (26 ページ)

Cisco AP776A - Nexus Converged Network Switch 5020 リリースノート
HP SPECIFIC KNOWN ISSUES
Problem Description: Issuing an "End to End Connectivity" to the EVA 4400/6400/8400 may
crash both EVA controllers at the same time.
Workaround: None.
Problem Description: Issuing an fcping to the EVA 4400/6400/8400 may crash the EVA
controller.
Workaround: None.
Problem Description: If it becomes necessary to move an EVA controller port to a different
port on the same C-series switch, or to a port on a different C-series switch, the corresponding
controller port may become unavailable.
Workaround: Restart the EVA controller.
Problem Description: EVA controllers running VCS 3.xxx may log into the C-series 4Gbps
modules at 1Gbps instead of the default 2Gbps.
Workaround: Set the switch port speed to 2Gbps.
Problem Description:
display as servers in the Fabric Manager topology diagram.
Workaround: Perform the following steps to change the display of the array from a host icon to
a storage icon.
1. Log into Fabric Manager
2. Under "Physical Attributes" open "End Devices"
3. Select "Hosts" and click on the "Enclosures" tab in the Information Pane
4. Under "Device Type" for the desired device, select "Disk"
5. Save changes by selecting the "Apply Changes" icon on the top left corner of the
Information Pane
Problem Description: VMware ESX on HP c-Class BladeSystem Server Blade using
QMH2462 HBAs and FC Pass-Thru Module may fail to log into the C-series MDS 9216, MDS
9216A, or 16-port switching module.
Workaround: Set the switch port mode to F.
Problem Description: If it becomes necessary to move an MSA1000/1500 controller port to a
different port on the same C-series switch, or to a port on a different C-series switch, the
corresponding controller port may become unavailable.
Workaround: Restart the MSA 1000/1500 controller.
Problem Description: If an EVA controller running VCS 3.xxx is restarted, paths may fail to
return on the C-series MDS 9020.
Workaround: Disable and then re-enable the port the EVA is plugged into.
Problem Description: EVA controllers running XCS 5.1xx or later may fail to log into the C-
series switches.
Workaround: Set the switch port mode to F or FX and specify the speed (2Gbps or 4Gbps).
Should the EVA controller fail to log in, unplug and reinsert the fibre channel cable.
21
The EVA4400/6400/8400 and MSA2000 series storage arrays may
MDS Multilayer Director & Multilayer Fabric Switches Release Notes