- ページ 17

ネットワーク・ルーター Digisol DG-IS4508HPのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Digisol DG-IS4508HP 18 ページ。 Industrial ethernet poe l2 switches

Digisol DG-IS4508HP ユーザーマニュアル

Chapter 4 Hardware Troubleshooting

4.1 Trouble analyzing

The key to troubleshooting is to separate trouble from the system. By analyzing what
system should do and what system is doing, troubleshooting becomes easy. Think of
the following systems while analyzing troubles:
Power and cooling system—Power and cooling fan;
Ports, cables and connections—ports on the front panel of the switch and cables
connected to the ports.
4.1.1

Power and cooling system breakdown

Examine the following conditions to separate troubles:
The power is "ON". Make sure the cooling fan is working normally. If cooling fan
is not working normally, check the fan;
Examine the environment. The switch cannot be overheated. Make sure the
inhale and exhale hole of the switch is clean. Refer to "General Requirement for
Working Environment". The temperature of the switch working environment is
0-40℃ (32-104
If switch is not working and "PWR" indicator is not light, check the power supply.
4.1.2

Ports, cables and connections breakdown

To separate problems, check the follow status:
If switch port is unable to link, check the connection. Make sure the connection
is normal;
If the power is "ON", check the power supply and power cord;
If the system is working but the console port is not, make sure the console port
configurations are as follows: 115200 baud rate, 8-bit data bit, no parity bit, 1
stop bit and no flow control.
DG-IS4508HP/IS4512HP/IS4514HP Hardware Installation Guide
º
).
F
17