Setting
1
0
Parameter 10: Timer functionality (auto - off)
Size: 2 Byte, Default Value: 0
Setting
0
1 - 32767
Parameter 11: ALL ON/ALL OFF function
Parameter allows for activation/deactivation of Z-Wave commands enabling/disabling all devices located in direct range of the main controller.
Size: 2 Byte, Default Value: 255
Setting
0
1
2
255
Parameter 13: Force auto-calibration
Changing value of this parameter will force the calibration process. During the calibration parameter is set to 1 or 2 and switched to 0 upon completion.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
Parameter 14: Auto-calibration status
This parameter determines operating mode of the Dimmer 2 (automatic/manual settings).
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 15: Burnt out bulb detection
Function based on the sudden power variation of a specific value, interpretedas a LOAD ERROR.
CAUTIONParameter 15 is relevant only when parameter 58 is set to 0 and the control modeis consistent with the mode set during the calibration process
(parameter 30).
Size: 1 Byte, Default Value: 30
Setting
0
1 - 99
Parameter 16: Time delay of a burnt out bulb (parameter 15) or overload (parameter 39) detection
Time of delay (in seconds) for power variation detection, interpretedas a LOAD ERROR or OVERLOAD detection (too much power connectedto the Dimmer 2).
Size: 2 Byte, Default Value: 5
Setting
0
1 - 255
Parameter 19: Forced switch on brightness level
If the parameter is active, switching on the Dimmer 2 (S1 single click)will always set this brightness level)
Size: 1 Byte, Default Value: 0
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGD-212
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGD-212
Description
the Dimmer saves its state before power failure.
the Dimmer 2 does not save the state before a power failure, it returns to off position
Description
Function disabled
time to turn off measured in seconds (1s-9.1h)
Description
ALL ON not active, ALL OFF not active
ALL ON not active, ALL OFF active
ALL ON active, ALL OFF not active
ALL ON active, ALL OFF active
Description
readout
force auto-calibration of the load without FIBARO Bypass 2
force auto-calibration of the load with FIBARO Bypass 2
Description
calibration procedure not performed or Dimmer 2 operates on manual settings
Dimmer 2 operates on auto-calibration settings
Description
function disabled
percentage value of power variation, compared to standard power consumption, measured during the
calibration procedure (to be interpreted as load error/burnt out bulb)
Description
detection of a burnt out bulb disabled
delay time in seconds
7/14