DOOR SENSING SWITCH, SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH ADJUSTMENT
1. Disconnect the power supply cord and remove the oven
from wall and remove outer case. (Refer to procedure of
"Removal of Oven from Wall" and "Outer case Removal")
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Remove the control panel assembly, referring to the
procedure of "CONTROL PANEL ASSEMBLY ,
CONTROL UNIT AND KEY UNIT REMOVAL".
If the door sensing switch, secondary interlock switch and
monitor switch do not operate properly due to a
misadjustment, the following adjustment should be made.
5. Loosen the two (2) screws holding latch hook to the oven
cavity front flange.
6. With door closed, adjust latch hook by moving it back and
forth, and up and down. In and out play of the door
allowed by the upper and lower position of the latch hook
should be less than 0.5mm. The vertical position of the
latch hook should be adjusted so that the door sensing
switch and secondary interlock switch are activated with
the door closed. The horizontal position of the latch hook
should be adjusted so that the monitor switch is activated
with the door closed.
7. Secure the screws with washers firmly.
8. Check all of the switches operation. If any switch has not
activated with the door closed, loosen screw and adjust
the latch hook position.
After adjustment, check the following.
1. In and out play of door remains less than 0.5mm when in
DOOR ASSEMBLY REMOVAL
1. Disconnect the power supply cord and remove the oven
from wall and remove outer case. (Refer to procedure of
"Removal of Oven from Wall" and "Outer case Removal")
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Remove the hood exhaust louver from the oven cavity by
pushing the right and left tabs of the hood exhaust louver.
(Refer to the procedure of "HOOD EXHAUST LOUVER
REMOVAL".)
5. Insert a putty knife (thickness of about 0.5mm) into the
gap A between the door stopper and the choke cover
as shown in Figure C-3 to free engaging parts.
6. Lift up the door stopper.
7. Now, the door stopper is free from the door assembly.
8. Lift up the door assembly to release the upper and lower
door hinge pins from the upper and lower oven hinges.
9. Now, the door assembly is free.
Note: When the individual parts are replaced, refer to
"Door Disassembly".
DOOR ASSEMBLY RE-INSTALL
1. On re-installing door, insert the lower oven hinge to lower
door hinge pin.
2. Insert the upper oven hinge to the upper door hinge pin.
3. Shut the door (close the contacts of interlock switches).
the latched position. First check upper position of latch
hook, pushing and pulling upper portion of door toward
the oven face. Then check lower portion of the latch
hook, pushing and pulling lower portion of the door
toward the oven face. Both results (play in the door)
should be less than 0.5mm.
2. The door sensing switch and secondary interlock switch
interrupt the circuit before the door can be opened.
3. Monitor switch contacts close when door is opened.
4. The contact of door sensing switch and secondary
interlock switch open within 1.2mm gap between right
side of cavity face plate and door when door is open.
5. Re-install outer case and check for microwave leakage
around door with an approved microwave survey meter.
(Refer to Microwave Measurement Procedure.)
Figure C-1. Latch Switch Adjustments
DOOR REPLACEMENT
4. Make sure upper and lower oven hinges are inserted into
the upper an lower door hinge pins.
5. Make sure the door is parallel with oven face lines (left
and upper side lines) and door latch heads pass through
latch holes correctly.
6. Re-install the door stopper to the door assembly.
7. Re-install the hood exhaust louver to the oven cavity
front face plate.
Note: After any service to the door;
(A) Make sure that door sensing switch and secondary
interlock switch are operating properly. (Refer to
chapter "Test Procedures".)
(B) An approved microwave survey meter should be
used to assure compliance with proper microwave
radiation emission limitation standards.
After any servicing, make sure of the following :
1. Door latch heads smoothly catch latch hook through
latch holes and that latch head goes through center of
latch hole.
2. Deviation of door alignment from horizontal line of cavity
face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity
face plate.
4. Re-install outer case and check for microwave leakage
around door with an approved microwave survey meter.
(Refer to Microwave Measurement Procedure.)
32
Latch
Hook
Latch
Heads
Door
Sensing
Switch
Monitor
Fuse
Monitor
Door
Switch
Secondary
Interlock
Switch