- ページ 2

電子レンジ Sharp Carousel R-1851AのPDF 補足サービスマニュアルをオンラインで閲覧またはダウンロードできます。Sharp Carousel R-1851A 16 ページ。 Over the range microwave oven
Sharp Carousel R-1851A にも: 操作マニュアル (26 ページ), 操作マニュアル (26 ページ)

Sharp Carousel R-1851A 補足サービスマニュアル
R-1850A
R-185lA
R-l 852A
(a)
04
(d
(4
03
Do not operate or allow the oven to be operated with the door open.
Make the following
safety checks on all ovens to be serviced before activating the magnetron
or other microwave source, and make repairs as necessary:
(1) Interlock operation, (2) proper
door closing, (3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to
or loosening
of hinges and latches, (5) evidence of dropping or abuse.
Before turning on microwave power for any service test or inspection within the microwave gen-
erating compartments,
check the magnetron,
waveguide
or transmission
line, and cavity for
proper alignment,
integrity, and connections.
Any defective or misadjusted
components
in the interlock, monitor, door seal, and microwave
generation
and transmission
systems shall be repaired, replaced, or adjusted by procedures
described
in this manual before the oven is released to the owner.
A microwave
leakage check to verify compliance
with the Federal performance
standard
should be performed on each oven prior to release to the owner.
(RD21101U
I
(RD81001 U)
If the unit operates with the door open, service person should 1) tell the user not to operate the oven
and 2) contact SHARP ELECTRONICS
CORPORATION
and DHHS immediately.
Service personnel
should inform SHARP ELECTRONICS
CORPORATION
of any certified unit
found with emissions in excess of 4mW/cm2. The owner of the unit should be instructed not to use
the unit until the oven has been brought into compliance.
Before servicing
an operative
unit, perform a microwave
emission
check as per the Microwave
Measurement
Procedure outlined in the base model service manual.
If microwave emissions level
is in excess of the specified limit, contact
SHARP ELECTRONICS
CORPORATION
immediately
Q l-800-237-4277.