制御システム Crestron CP3のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Crestron CP3 8 ページ。 Automated processors
Crestron CP3 にも: クイック・スタート・マニュアル (2 ページ), クイック・スタート・マニュアル (2 ページ)

CP3 and CP3N
3-Series Control System® Automated Processors
The Crestron®
CP3
and
CP3N
are compact, rack-mountable 3-Series®
automated control processors with numerous integrated control ports.
Featuring the 3-Series control engine, the CP3 and CP3N unify the
disparate technologies in residential, commercial, and government
buildings so that they can communicate and work together intelligently.
The CP3N also supports the Crestron Control Subnet, which is an isolated
gigabit Ethernet network dedicated exclusively to Crestron devices.
NOTE:
The CP3 and CP3N are functionally similar. For simplicity within
this guide, the term "control system" is used to refer to both unless
otherwise noted.
In the Box
1
CP3 or CP3N, 3-Series Control System
Additional Items
2
Bracket, Rack Ear, 1U (2032122)
2
Connector, 3-Pin (2003575)
1
Connector, 4-Pin (2003576)
1
Connector, 5-Pin (2003577)
4
Connector, 8-Pin (2003580)
1
Connector, 9-Pin (2003581)
4
Foot, 0.5 in. x 0.5 in. x 0.23 in., Adhesive (2002389)
1
Cable, Power, 5 ft 10 in. (1.78 m) (2042043)
1
Power Pack, 24 VDC, 2.5 A, 100-240 VAC (2045873)
Install the Device
The control system can be mounted into a rack or placed on a flat
surface.
Mount into a Rack
The control system occupies 1U of rack space. Use the three screws from
the front part of each side panel, and a #1 Phillips screwdriver to attach
the two included rack ears to the device, as shown in the following
illustration. Then mount the control system into the rack using four
mounting screws (not included).
Rack Mounting Safety Precautions
Elevated Operating Ambient Temperature: If installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient temperature. Therefore,
consideration should be given to installing the equipment in an
Quick Start