水ポンプ Bitspower BP-DDCPLS42-PWMのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Bitspower BP-DDCPLS42-PWM 6 ページ。

Bitspower BP-DDCPLS42-PWM 取扱説明書
Bitspower DDC 4.2 Pump PWM
Dimension
Installation
Vertical
Notice
1
You can connect the PWM+Tach cable to any fan slot on the motherboard. And then the speed of the pump can be controlled by the fan PWM function. If not,
there will be no PWM and data display function.
2
The power cable should connect to the power supply to make the pump work.
If you only connect the Power Cable to the power supply, the pump will run at full speed.
Troubleshooting
If the pump doesn't operate, please replug the pump in several
times until it works normally.
If it still doesn't work, it is probably blocked by particles.
Drain the system and remove the pump housing. Open the pump
by removing the four housing screws at the bottom.
Remove the housing and pull out the rotor.Clean the rotor with a
clean cloth and purge all dirt from the pump housing.
Dimension In:mm
Horizontal
PWM+TACH cable
POWER cable
[ 1 ]
instruction manual
V2
Not permitted Upside down
SPECIFICATION
Max. flow
Max. head
Rated voltage
Rated current
Power consumption
Noise level
Max. temperature
9.6 LPM
4.34 M
12V DC
1.33 A
16 W
≦ 40dBA
70° C