Device description
2.3 Pin assignment
2.3
Pin assignment
Solder contact P4
Pin
1
2
3
4
P1 connector
The individual pins are connected to the solder contacts (P4).
Type: JST SM04B-SRSS-TB
Pin
1
2
3
4
P2 connector
Internal interface for production and manufacturing test, do not use.
2.4
LED status indicator
The operating states of the transponder are indicated by the LEDs. The states can be off ,
on
LED
10
Description / Function
Grounding
Rx - Input on the transponder, 3.3 V
Tx - Output on the transponder, 3.3 V
Supply voltage 3.3 V
Description / Function
Rx - Input on the transponder, 3.3 V
Tx - Output on the transponder, 3.3 V
Grounding
Supply voltage, VCC, 3.3 V ±100 mV
and flashing .
Meaning
Flashes every three seconds when the transponder is active
Is off when the transponder is inactive
Lights up for 0.6 seconds on system start
Flashes every 0.1 seconds after a watchdog reset
SIMATIC RTLS PCB OEM PULSE
Operating Instructions, 03/2020, C79000-G8976-C552-03