Charging instructions

Mount the charging station in a location with cool ambient temperature. Then, fully charge
the device using the charging station.
The temperature of the device and the ambient temperature must not exceed 40 °C for the
device to be charged. The higher the temperature, the longer it takes to charge the device.
If the device exceeds 55 °C during charging, remove the device from the charging station.
Allow the device to cool down and try charging it again. If the device becomes too hot again,
remove the device from the charging station and contact customer service.
The battery has a natural self-discharge. When stored in a state not fully charged, the device
is discharged after approximately 6 months and must be recharged. If the device is
completely discharged, the integrated battery may be damaged.
To charge, insert the device fully in a charging bay of the charging station. The front of the
device must face away from the side of the cable guide. The start and status of the charging
process are signaled via the LED display on the device. A full charging process takes
approximately 8.5 hours. To ensure correct operation of all 10 charging bays and to avoid
damage to the devices, only use the power supply unit provided with the charging station.
Read also the descriptions of the operating states of the device in section "LED status
indicator, display & function key (Page 10)".