Digital output
The digital output can switch resistive, capacitive and inductive loads. The current is
automatically limited to these functions. Observe the value for the maximum current in
section "Technical specifications (Page 17)". A freewheeling diode D
inductivities.
Digital input
The device has 8 digital inputs, 1 to 8. Each has a range from 0 to 24 V with an impedance of
4.7 kOhm.
Input 8 is different in that the impedance can be switched off. The input impedance is
110 kOhm in this case.
ANT1 - Antenna - RP-SMA plug-in connector
Use only the accessories specified in section "Order data RTLS4460T (Page 9)".
SIMATIC RTLS4460T
Operating Instructions, 05/2021, C79000-G8976-C522-04
Device description
2.3 Pin assignment
is required for
V