- ページ 7

産業機器 Siemens SIRIUS 3SK1のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Siemens SIRIUS 3SK1 14 ページ。

Siemens SIRIUS 3SK1 取扱説明書

Safety instructions

2.1

User responsibility for system design and function

The products described here were developed to perform safety-related functions as part of an
overall installation or machine.
A complete, safety-related system is generally equipped with sensors, evaluation units, and
signaling units, and uses reliable shutdown concepts.
It is the responsibility of the manufacturer of a system or machine to ensure that the product
functions properly.
Siemens AG, its regional offices, and associated companies (hereinafter referred to as "Siemens")
cannot guarantee all the properties of an entire plant, system or machine that has not been
designed by Siemens.
Nor can Siemens assume liability for recommendations that appear or are implied in the
following description. No new guarantee, warranty, or liability claims beyond the scope of the
Siemens general terms of supply are to be derived or inferred from the following description.
2.2

General safety notes

Note
SILCL 3 in accordance with IEC 62061:2005PL e / Cat. 4 in accordance with EN ISO 13849-1:
2015
3SK11 safety relays are designed in such a way that applications up to SILCL 3 according to IEC
62061, PL e / Cat. 4 in line with ISO 13849-1 can be implemented.
Note
Safe state
The basis of the safety function is the definition of the safe state. In the case of safety relays, this
is the "OFF state", i.e. an open contact for sensors or shutdown of the actuators.
Hazardous voltage. Can cause death or serious injury
To ensure touch protection and degree of protection IP20, screw in all screws which are not
used for conductor clamping and close the terminal covers.
SIRIUS 3SK1 Advanced Safety Relays - special versions