- ページ 23
産業機器 Siemens SITRANS WW200のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Siemens SITRANS WW200 36 ページ。 Weighfeeders
①
②
③
④
Note
Load cell may appear different than shown.
7.9.2
Installing new load cell
1. Slide the new load cell into position.
2. Install the two bottom load cell mounting bolts and tighten them by hand.
The load cell should now be resting against the overload bolt.
3. Install the two top/front load cell mounting bolts. Tighten them by hand.
4. Start with the bottom load cell mounting bolts and tighten them to the torque value indicated
in the load cell instructions. Now tighten the two top/front load cell mounting bolts to the
same torque value.
SITRANS WW200
Operating Instructions, 06/2018, A5E33560654-AC
4
Weigh deck
Belt
Top load cell mount
Bottom load cell mount
1
2
3
7
6
5
⑤
Load cell
⑥
Shipping bolt
⑦
Overload bolt
Commissioning
7.9 Load cell replacement
23