- ページ 10
産業機器 Siemens SIWAREX WL270 CP-S SAのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Siemens SIWAREX WL270 CP-S SA 40 ページ。 Mounting plates cp-s sa
Siemens SIWAREX WL270 CP-S SA にも: 取扱説明書 (38 ページ)
Description
3.1 Application
Danger to life from collapse of the structure
Without any protective measures the structure can collapse if the load cell is not installed
correctly. Therefore supporting structures complying with the general rules of mechanical
engineering must be designed by the customer for installing the pressure piece set.
As an alternative installation units from the product range of Siemens can be used.
3.1.2
Lifting protection
The lifting protection prevents the load bearing implements from being lifted off of the load
cells.
If there is a risk of the load bearing implement being lifted or toppled, then lifting protection is
required. This is required in the case of lightweight containers and tall, outdoor silos.
3.1.3
Overload protection
The overload protection protects load cells from a load that is too great.
There is overload protection against excessive loads in the measuring direction and overload
protection against excessive transverse forces.
Transverse forces are caused by, for example, wind, filling processes, acceleration, or
conveyor belt friction. If these forces exceed certain values, the load cells must be protected
from them.
10
WARNING
Operating Instructions, 11/2010, A5E03323543B
CP-S SB