- ページ 11

アクセサリー Digital Home System DHS-ZW-SNMT-01のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Digital Home System DHS-ZW-SNMT-01 14 ページ。 Z-wave motion sensor

3.
Click " Save Lua" and then SAVE in Vera and wait till new settings are saved.
Changing Wakeup Interval in Vera
NOTE:
The sensor sleeps for the duration of the Wake Up interval, which defaults to 1800
seconds or 30 minutes.
Keep in mind that them more often the device is waked up the more energy it con-
sumes. As a result battery will run down much quicker.
Example of setting new Wakeup Interval of 300 seconds or 5 minutes
1.
Click " Save Lua" and then SAVE in Vera and wait till new settings are saved.
"_Motion Sensor" box -> Settings
Wakeup Interval (seconds) = <new desired value>
Poll this device at most once every = <new desired value, the same as new Wakeup Inter-
val>
2.
Click SAVE in Vera and wait till new settings are saved in Vera.
3.
Please press the tamper switch at the back of the device for 3-8 seconds.
4.
After 3-5 seconds, the led will blink three times; you can now release the button.
5.
Immediately click on "Con gure node right now" button on "_Motion Sensor" box /
Settings tab.
6.
Wait till the new settings are propagated to the Sensor.

Frequently Asked Questions

Q: I can't have my Z-Wave sensor included into my Z-Wave network, what am I doing
wrong?
A:
1. Is the controller ready to include any device into the Z-Wave network? If the con
troller is not in
Include or exclude mode, the Z-Wave sensor cannot be included or excluded.
2. The Z-Wave sensor is already included in a Z-Wave network. Exclude the Z-Wave
sensor and try to include it again.
Q: Why doesn't the Z-Wave sensor detect any movement?
A:
1. The Z-Wave sensor isn't included in a Z-Wave network. Include it and try it again.
2. The batteries are almost empty, try putting new ones in.
Q: The temperature report of the Z-Wave sensor is incorrect.
A:
1. The Z-Wave sensor is placed directly in the sun, which makes the temperature in
the housing of the Z-Wave sensor hotter than elsewhere in the room.
2. The calibration is not the same as your other temperature sensor; it is possible to
do a re-calibration of the temperature sensor.
Q: I have con gured a value but when I request it, it is not changed?
A:
It is mandatory that the correct size is used while con gure a parameter; go to the
documentation about the con guration command class to check if the right size is
used during con guration. If the wrong size is used the frame is ignored totally.
Q: I have con gured a new value and when I request it the correct value is returned but the
behaviour is still the same?
A:
Some con guration parameters have limits of what they can do, go to the docu
mentation about con guration to check if the value of the con gured parameter is
out o limit.
Q: When I mount the Z-Wave sensor it performs its standard mounting routine but after 8
seconds the indicator light doesn't go on for 1 second but blinks 6 times.
A:
blinking 6 times can mean:
1. Z-Wave sensor is not included
2. Z-Wave sensor is not associated
3. Z-Wave sensor can't reached his destination
If all three options are corrected, Z-Wave sensor is will operate correctly and can be
mounted again.
11