- ページ 5

プロジェクター Epson BE-Z8050WのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Epson BE-Z8050W 28 ページ。 Esc/vp21 command user’s guide for business projectors

Epson BE-Z8050W ユーザーマニュアル

4. Projector state and commands

4.1. Standby state (Operation indicator is in orange)
When a projector is in a standby state, executable commands depends on projector models and standby configuration (network
on, network off). Refer to the following table.
Models
61/81, 830/835, 821/828
740/745/732/737, 760/765
S3/S4, 765/760/755/750
62/82/X3(76), 6100/6000
1715/1710/1705/1700
1815/1810/1825
S5/X5/83/822/823/83+/822+,
260/280, 400W/410W
G5350/G5300/G5100/G5200W/
G5150/G5000, 6110/6010,
1735W/1730W/1725/1720
84/85/824/825/826W
Z8000WU/Z8050W
S7/X7/W7, S8/X8/W8
1900/1910/1915/1920W/1925W
84H/85H/825H/826H
440W/450W/460
, and later model
7800/7850
8300/8350/9300
7900/7950
(note3)
Others
(note1)EMP-61/81/830/835/740/745/821/828 returns "ERR" when it received commands other than PWR ON, PWR?, LAMP? and
Null commands.
(note2) EMP-7800/7850 returns "ERR" when it received commands other than PWR ON, PWR?, SOURCE? and Null commands.
(note3) EMP-8300/9300 returns "ERR" when it received commands other than PWR ON, SOURCE xx, PWR?, SOURCE? and Null
commands
All projectors returns "ERR" when the command format is not good. All projectors returns "ERR" when the projector is not ready to
reply the command. A null command is command name for "ENTER" or "RETURE" key of the keyboard the reply is ":".
4.2. Power on state (Operation indicator is in green)
All commands are executable.
ESC/VP21 Command User's Guide for Business Projectors
Configuration
Network on/off
Network on
Network off
-
PWR ON
PWR?
LAMP?
PWR ON, PWR?, SOURCE?,
Null command(note1)
PWR ON(Note2)
~ 5~
Executable commands