en Automatic switch-off
7 Automatic switch-off
If you do not change the settings of a hotplate for a
long time, automatic switch-off will be activated.
When the hotplate switches off depends on the heat
setting selected (1 to 10 hours).
The heat to the hotplate is switched off.
sidual heat indicator / flash alternately on the hot-
plate display.
8 Basic settings
You can configure the appliance to meet your needs.
8.1 Overview of the basic settings
You can find an overview of the basic settings and the
default factory settings here.
Dis-
Selection
play
Automatic childproof lock
– Switched off
– Switched on
– Manual and automatic childproof lock are
switched off.
Signal tone
– Confirmation signal and operating error
signal are switched off. The main switch sig-
nal remains switched on.
– Only the operating error signal is
switched on.
– Only the confirmation signal is switched
on.
– Confirmation signal and operating error
signal are switched on.
Activation of the heating elements
– Switched off
– Switched on
– The last setting before switching off the
1
hotplate.
Time for selecting hotplates
– Unlimited: The last hotplate selected can
always be adjusted without having to select it
1
again.
– You can adjust the last hotplate selected
within 10 seconds after selecting it. After this
time you have to select the hotplate again be-
fore adjusting it.
Resetting to the factory settings
– Switched off.
– Switched on.
1
Factory setting
8
and the re-
1
1
1
7.1 Continuing cooking after automatic
switch-off
Touch any touch field.
1.
a The display goes out.
Reset.
2.
8.2 Changing basic settings
Requirement: The hob is switched off.
Switch on the hob.
1.
Within the next 10 seconds press and hold
2.
approx. 4 seconds.
a
and
flash alternately on the left-hand display.
lights up on the right-hand display.
a
Repeatedly touch
3.
pears on the left-hand display.
Use
or
to set the required value.
4.
Press and hold
5.
a The setting is activated.
Tip: To exit the basic settings, switch off the hob using
. Switch the hob on again and reset.
until the required indicator ap-
for 4 seconds.
for