- ページ 6

ホブ Siemens EB6B P SeriesのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Siemens EB6B P Series 12 ページ。 Built-in gas hob
Siemens EB6B P Series にも: ユーザーマニュアル (12 ページ)

Siemens EB6B P Series 取扱説明書

Gas burners

en
Code
HZ298108 Additional wok grid: cast iron (3.3 kW)
HZ298110 Additional wok grid: Enamelled steel
HZ298114 Additional espresso maker grid
HZ298105 Simmer Plate
HZ298104 Simmer cap
The manufacturer accepts no liability if these
accessories are not used or are used incorrectly.
ÄGas burners
There are indications to show which burner each
G a s b u r n e r s
control knob operates.
It is essential to ensure that all the burner parts and pan
supports are correctly installed for the appliance to
work correctly. Do not swap the burner caps around.

Switching on manually

Press the chosen burner control knob and turn it
1.
anticlockwise to the required setting.
Use any type of lighter or flame (cigarette lighter,
2.
matches, etc.) and bring it close to the burner.

Switching on automatically

If your hob can be switched on automatically (ignition
sparkers):
Press the chosen burner control knob and turn it
1.
anticlockwise to the maximum power setting.
While the control knob is still pressed down, sparks
are produced on all burners. The flame ignites.
Release the control knob.
2.
Turn the control knob to the required setting.
3.
If it does not come on, turn the control knob to the off
setting and repeat the steps above. This time, press and
hold the control knob for longer (up to 10 seconds).
6
:
Warning – Risk of deflagration!
If after 15 seconds the flame does not ignite, switch off
the burner and open a nearby window or door. Wait at
least one minute before trying to switch the burner back
on.

Safety system

Your hob is equipped with a safety system
(thermocouple) that cuts off the gas when the burners
are accidentally switched off.
ignition sparker
1
thermocouple
2
To ensure that this device is active:
Switch on the burner as usual.
1.
Without releasing the control knob, press and hold it
2.
down firmly for 4 seconds after lighting the flame.

Switching off a burner

Turn the corresponding control knob clockwise to the 0
setting.

Power levels

The progressive control knobs can be used to control
the power needed, from minimum to maximum power.
Ú
Setting
Control knob off
˜
High flame
Maximum capacity or aperture and electric-
ity on
Low flame
Minimum capacity or aperture

Warnings

It is normal to hear a soft whistling noise while the
burner is operating.
When first used, it is normal for the burner to give off
odours. This does not pose any risk and does not
indicate a malfunction. They will disappear in time.
An orange-coloured flame is normal. This is caused by
the presence of dust in the atmosphere, spilt liquids,
etc.
If the burner flames are accidentally blown out, switch
off the burner operating control knob and do not try to
relight it for at least 1 minute.
A few seconds after the burner is switched off, a sound
(thud) will be produced. This is not a fault - this means
that the safety device is no longer operating.