- ページ 18

ホブ Siemens EH8 SB3 SeriesのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Siemens EH8 SB3 Series 20 ページ。

Siemens EH8 SB3 Series 取扱説明書

Fixing malfunctions

Malfunctions are usually due to small details. Before calling the
Technical Assistance Service, you should consider the
following advice and warnings.
Indicator
Malfunction
none
The electric power supply has been cut off. Use other electrical appliances to check whether there has been a
The appliance has not been correctly
connected following the connection
diagram.
Electronic system malfunction.
The control panel is damp or an object is
flashes
"
resting on it.
Electronic system malfunction.
+ number /
+ number /
š
+ number
¡
There is an internal error in the operation.
"‹
The electronic system has overheated and
the corresponding hotplate has been
switched off.
The electronic system has overheated and
"...
all hotplates have been switched off.
Supply voltage outside normal operating
—‚
limits.
The hotplate has overheated and has
/
—ƒ
—„
switched off in order to protect its cooking
surface.
* If the warning persists call the Technical Assistance Service.
Do not rest hot pans on the control panel.
18
Solution
power cut.
Check that the appliance has been connected correctly according to
the connection diagram.
If in the above checks, the malfunction is not resolved, contact the
Technical Assistance Service.
Dry the control panel area or remove the object.
Unplug the hob from the mains. Wait about 30 seconds before
plugging it in again.*
Unplug the hob from the mains. Wait about 30 seconds before
plugging it in again.*
Wait until the electronic system has cooled down completely. Then
push any symbol on the hob.*
Please contact the local electricity board.
Wait until the electronic system has cooled down sufficiently before
switching it back on.