6SHFLILFDWLRQV
Operating input voltage
Input Frequency
Surge Suppression
Ethernet Interface
Serial I/O Hardware
Outlets & plugs
Password transmission
Circuit Breakers
Control Relays
Power cords
Power fail hold-over time
Current Metering
Voltage Metering
Switches & Controls
Size
Indicators
Weight
Operating temperature
Enclosure material
Ethernet Power Controller II
14
100-130VAC or 200-277VAC switch
selectable
47-63Hz
Dual MOV, 3500J rating
10/100 autosensing, Static IP, TCP
port selectable, 8 pin RJ-45 with
internal FCC filtering
RS-232, 2 ports, SW support pending
18 x outlets NEMA 5-15R, 2 15A
plugs, others available custom order
Encrypted, base 64
2x15A thermal, slow blow, pushbutton
T-90, 277V, 15-25A contact rating
14AWG low loss stranded, UL SJT
FX3C VW-1 150ºC rating
900ms minimum (all on)
2% or .3A accuracy, 0-20A
100-300VAC, 2% accuracy
On,off,remote switch for each outlet
On/off switch for each power bus
Processor reset-to-default button
19" RETMA rack. 2-U 3.5" height
Power on (8x LEDs), Outlet Status
(8x LEDs), Link, Act
Audio alert 81dBA at case
Bare unit 11.2 lbs, Ship wt. 12.1lbs
-30º to 17ºF, -34º to 77ºC
Cold rolled steel, non flammable
powder coated, no plastics
www.digital-loggers.com
/LPLWHG )LYH <HDU :DUUDQW\
The terms of this warranty may be legally binding. If you do not agree to the
terms listed below, return the product immediately in original unopened
condition for a full refund. The purchaser assumes the entire risk as to the
results and performance of the unit. DLI warrants this power controller to be
free from major defects. No agency, country, or local certifications are
included with this unit. It is the responsibility of the user to obtain such
certifications if they are necessary. DLI's entire liability and exclusive remedy
as to defective hardware shall be, at DLI's option, either (a) return of the
purchase price or (b) replacement or repair of the hardware that does not
meet DLI's quality control standards and has been returned through proper
RMA procedures. DLI's liability for repair or replacement is to DLI's customer
ONLY. WARRANTY SERVICE DOES NOT INCLUDE SOFTWARE OR
HARDWARE UPGRADES. No warranty service will be provided without an
original invoice from DLI and an RMA number provided by technical support.
RMA material must be shipped prepaid to DLI. RMA numbers are valid for
15 days from date of issue. This warranty does not cover products modified,
subjected to rough handling, or used in applications for which they were not
originally intended. No oral advice or verbal warranties made by DLI's
employees, dealers, or distributors shall in any way increase the scope of
this warranty. DLI makes no warranty as to merchantability or fitness for any
particular purpose. DLI assumes no liability for incidental or consequential
damages arising from the use or inability to use this product. This warranty
gives you specific legal rights. You may also have other rights that vary from
state to state. Since some states do not allow the exclusion of liability for
consequential damages, some of the above limitations may not apply to you.
DIGITAL LOGGERS, INC.
2695 Walsh Avenue
Santa Clara, CA 95051
FAX (408) 541-8459
www.digital-loggers.com
© 2007 DLI This product is protected by pending US patents and foreign patents
Release 1.2.1 Updated Wednesday, October 31, 2007.
Release 1.21 Updated Friday, May 23, 2008.
Ethernet Power Controller II
15